Syringe pump extruder and curing system for 3D printing of photopolymers.

HardwareX

Department of Mechanical Engineering, University of New Orleans, United States.

Published: April 2021

Development of new additive manufacturing materials often requires the production of several batches of relatively large volumes in order to print and test objects. This can be difficult for many materials that are expensive or difficult to produce in large volumes on the laboratory scale. Bioprinter systems are advantageous in this regard, however, commercial systems are expensive or do not have the ability to use photopolymers. Herein, we outline a Syringe Pump Extruder and Curing System (SPECS) modification for inexpensive filament-based 3D printers which enables the use of standard bioplotter materials and photopolymers. The system is capable of using multiple syringe volumes and needle sizes that can be quickly and easily exchanged. The SPECS modification is demonstrated using a Prusa i3 mk3 fused filament fabrication printer to print several 3D objects and films using stereolithography (SLA) photopolymer resin. Geometric accuracy in the X, Y, and Z directions was ±0.1 mm using a 5 ml syringe, 22-gauge needle, and commercial SLA resin. The SPECS system could be of great benefit for laboratories pursing material development in the area of additive manufacturing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9041271PMC
http://dx.doi.org/10.1016/j.ohx.2021.e00175DOI Listing

Publication Analysis

Top Keywords

syringe pump
8
pump extruder
8
extruder curing
8
curing system
8
additive manufacturing
8
large volumes
8
specs modification
8
syringe
4
system
4
system printing
4

Similar Publications

Construction and experimental validation of electrochemical cells with multiple electrodes in a microfluidic channel is described. Details of the fabrication of the electrodes and polydimethylsiloxane channel using soft lithography methods are given. Calibration of the collection efficiencies and transit times between electrodes validate the use of these cells for fast electrochemical detection of soluble species.

View Article and Find Full Text PDF

Inkjet printing techniques are often used for bioprinting purposes because of their excellent printing characteristics, such as high cell viability and low apoptotic rate, contactless, commercial availability, and low cost. However, they face some disadvantages, such as the use of bioinks of low viscosity, cell damage due to shear stress caused by drop ejection and jetting velocity, as well as a narrow range of available bioinks that still challenge the inkjet printing technology. New technological solutions are required to overcome these obstacles.

View Article and Find Full Text PDF

Background: Prophylactic parenteral administration of antibiotics is strongly recommended to prevent surgical site infection (SSI). Cefoxitin is mainly administered intravenously in colorectal surgery. The current standard method for administering prophylactic antibiotics in adults is to administer a fixed dose quickly before skin incision.

View Article and Find Full Text PDF

RAFT Dispersion Polymerization of 2-Hydroxyethyl Methacrylate in Non-polar Media.

Macromolecules

December 2024

Dainton Building, Department of Chemistry, University of Sheffield, Brook Hill, Sheffield, South Yorkshire S3 7HF, U.K.

We report the reversible addition-fragmentation chain transfer (RAFT) dispersion polymerization of 2-hydroxyethyl methacrylate (HEMA) in -dodecane using a poly(lauryl methacrylate) (PLMA) precursor at 90 °C. This formulation is an example of polymerization-induced self-assembly (PISA), which leads to the formation of a colloidal dispersion of spherical PLMA-PHEMA nanoparticles at 10-20% w/w solids. PISA syntheses involving polar monomers in non-polar media have been previously reported but this particular system offers some unexpected and interesting challenges in terms of both synthesis and characterization.

View Article and Find Full Text PDF

Background: Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!