Inter-observer agreement of preoperative cardiopulmonary exercise test interpretation in major abdominal surgery.

BMC Anesthesiol

Department of Epidemiology, Care and Public Health Research Institute (CAPHRI), Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands.

Published: April 2022

Background: Accurate determination of cardiopulmonary exercise test (CPET) derived parameters is essential to allow for uniform preoperative risk assessment. The objective of this prospective observational study was to evaluate the inter-observer agreement of preoperative CPET-derived variables by comparing a self-preferred approach with a systematic guideline-based approach.

Methods: Twenty-six professionals from multiple centers across the Netherlands interpreted 12 preoperative CPETs of patients scheduled for hepatopancreatobiliary surgery. Outcome parameters of interest were oxygen uptake at the ventilatory anaerobic threshold (V̇O) and at peak exercise (V̇O), the slope of the relationship between the minute ventilation and carbon dioxide production (V̇E/V̇CO-slope), and the oxygen uptake efficiency slope (OUES). Inter-observer agreement of the self-preferred approach and the guideline-based approach was quantified by means of the intra-class correlation coefficient.

Results: Across the complete cohort, inter-observer agreement intraclass correlation coefficient (ICC) was 0.76 (95% confidence interval (CI) 0.57-0.93) for V̇O, 0.98 (95% CI 0.95-0.99) for V̇O, and 0.86 (95% CI 0.75-0.95) for the V̇E/V̇CO-slope when using the self-preferred approach. By using a systematic guideline-based approach, ICCs were 0.88 (95% CI 0.74-0.97) for V̇O, 0.99 (95% CI 0.99-1.00) for V̇O, 0.97 (95% CI 0.94-0.99) for the V̇E/V̇CO-slope, and 0.98 (95% CI 0.96-0.99) for the OUES.

Conclusions: Inter-observer agreement of numerical values of CPET-derived parameters can be improved by using a systematic guideline-based approach. Effort-independent variables such as the V̇E/V̇CO-slope and the OUES might be useful to further improve uniformity in preoperative risk assessment in addition to, or in case V̇O and V̇O are not determinable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9055752PMC
http://dx.doi.org/10.1186/s12871-022-01680-yDOI Listing

Publication Analysis

Top Keywords

inter-observer agreement
20
self-preferred approach
12
systematic guideline-based
12
guideline-based approach
12
agreement preoperative
8
cardiopulmonary exercise
8
exercise test
8
preoperative risk
8
risk assessment
8
approach systematic
8

Similar Publications

The assessment of biological maturation is a central topic in pediatric exercise sciences. Skeletal age (SA) reflects changes in each bone of the hand and wrist from initial ossification to the adult state. This study examined intra-observer and inter-examiner agreement is Greulich-Pyle (GP) assessments of SA in 97 male tennis players 8.

View Article and Find Full Text PDF

Background/aim: To explore transfer learning (TL) techniques for enhancing vertical root fracture (VRF) diagnosis accuracy and to assess the impact of artificial intelligence (AI) on image enhancement for VRF detection on both extracted teeth images and intraoral images taken from patients.

Materials And Methods: A dataset of 378 intraoral periapical radiographs comprising 195 teeth with fractures and 183 teeth without fractures serving as controls was included. DenseNet, ConvNext, Inception121, and MobileNetV2 were employed with model fusion.

View Article and Find Full Text PDF

Advances in the Application of Artificial Intelligence in the Ultrasound Diagnosis of Vulnerable Carotid Atherosclerotic Plaque.

Ultrasound Med Biol

January 2025

Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, China; Departments of Medical Imaging, Quanzhou Medical College, Quanzhou, China. Electronic address:

Vulnerable atherosclerotic plaque is a type of plaque that poses a significant risk of high mortality in patients with cardiovascular disease. Ultrasound has long been used for carotid atherosclerosis screening and plaque assessment due to its safety, low cost and non-invasive nature. However, conventional ultrasound techniques have limitations such as subjectivity, operator dependence, and low inter-observer agreement, leading to inconsistent and possibly inaccurate diagnoses.

View Article and Find Full Text PDF

Objective: The objective of this study was to evaluate the effectiveness of oblique radiographic projection using the intraoral paralleling technique in detecting various peri-implant bone defects.

Methods: Artificial mandibular models with appropriate radiopacity were created. An alveolar bone model without bone defects and models with 12 types of peri-implant bone defects (buccal, circumferential, and mixed types with different widths and depths) were created.

View Article and Find Full Text PDF

Optimizing hip MRI: enhancing image quality and elevating inter-observer consistency using deep learning-powered reconstruction.

BMC Med Imaging

January 2025

Department of Magnetic Resonance Imaging, The First Affiliated Hospital, Zhengzhou University, Zhengzhou, 450052, China.

Background: Conventional hip joint MRI scans necessitate lengthy scan durations, posing challenges for patient comfort and clinical efficiency. Previously, accelerated imaging techniques were constrained by a trade-off between noise and resolution. Leveraging deep learning-based reconstruction (DLR) holds the potential to mitigate scan time without compromising image quality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!