Analyzing the radiation spectra of impurity ions is a widely applied diagnostic scheme for plasma ion temperature and rotation measurements on tokamaks. High precision wavelength calibration is a prerequisite for the accurate measurement of plasma parameters, especially for plasma rotation. Furthermore, the sparseness or absence of the standard spectral lines brings calibration challenges due to the narrow wavelength range. A precise wavelength calibration method is demonstrated in which the comb-like spectra generated by the Fabry-Pérot etalon can lock a series of fixed peaks as reference points in a wide wavelength range. The equal frequency intervals of the comb-like spectra are further corrected using several characteristic neon lines of known wavelengths. The experimental results indicate that the wavelength accuracy obtained by this calibration method is less than 0.005 nm, which corresponds to a rotation speed of 2.3 km/s in the toroidal direction for the beam emission spectroscopy spectrometer installed on the experimental advanced superconducting tokamak. Taking the O V(650.024 nm, n = 4 → 3) line as an example, the maximum difference in the oxygen ion rotation velocity is 3.8 km/s for the absolute rotation of ∼25 km/s, when compared with the calibration results of a standard lamp.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0083784DOI Listing

Publication Analysis

Top Keywords

wavelength calibration
12
calibration method
12
high precision
8
precision wavelength
8
fabry-pérot etalon
8
experimental advanced
8
advanced superconducting
8
superconducting tokamak
8
wavelength range
8
comb-like spectra
8

Similar Publications

It can be difficult to employ optical techniques for analyzing biological structures smaller than or comparable to the wavelength of light, such as extracellular vesicles or some types of bacteria. Biological light scattering spectroscopy (LSS), developed to address this problem, has been successfully used for characterizing tissue on cellular and subcellular scales. At the same time, calibration with a reference sample of known optical properties can complicate LSS measurements.

View Article and Find Full Text PDF

Significance: Dynamic phantoms capable of changing optical properties by control are essential for standardizing and calibrating spectroscopy systems such as the pulse oximeter. However, current liquid dynamic phantoms containing human blood have a short shelf life and require complex experimental setups. Some solid dynamic phantoms are influenced by the angular-dependent performance of the liquid crystal display (LCD), some have a low spatial resolution, and some have slow control of optical properties.

View Article and Find Full Text PDF

Novel Spectrophotometric Method for Robust Detection of Trace Copper and Cobalt in High-Concentration Zinc Solution.

Molecules

December 2024

Hunan Province Key Laboratory of Southwest, Hunan Academician Workstation, School of Information Science and Engineering, Shaoyang University, Shaoyang 422000, China.

In the purification process of zinc hydrometallurgy, the spectra of copper and cobalt seriously overlap in the whole band and are interfered with by the spectra of zinc and nickel, which seriously affects the detection results of copper and cobalt in zinc solutions. Aiming to address the problems of low resolution, serious overlap, and narrow characteristic wavelengths, a novel spectrophotometric method for the robust detection of trace copper and cobalt is proposed. First, the Haar, Db4, Coif3, and Sym3 wavelets are used to carry out the second-order continuous wavelet transform on the spectral signals of copper and cobalt, which improves the resolution of copper and cobalt and eliminates the background interference caused by matrix zinc signals and reagents.

View Article and Find Full Text PDF

The non-destructive detection of fruit quality is indispensable in the agricultural and food industries. This study aimed to explore the application of hyperspectral imaging (HSI) technology, combined with machine learning, for a quality assessment of pears, so as to provide an efficient technical method. Six varieties of pears were used for inspection, including 'Sucui No.

View Article and Find Full Text PDF

Background: Nemonoxacin is a novel non-fluorinated quinolone antibiotic for the treatment of community-acquired pneumonia. To investigate the pharmacokinetics (PK) of nemonoxacin, a simple and sensitive high-performance liquid chromatography assay (HPLC) was needed.

Methods: An HPLC method with fluorescence (FL) detection was developed for the quantification of nemonoxacin in plasma and bile.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!