Aim: To determine the diagnostic accuracy of an automated artificial intelligence derived right ventricle/left ventricle diameter ratio (RV/LV) computed tomography pulmonary angiography (CTPA) analysis tool to detect pulmonary hypertension (PH) in patients with suspected PH referred to a specialist centre.

Materials And Methods: The present study was a retrospective analysis of a prospectively maintained database of 202 consecutive patients with suspected PH, who underwent CTPA within 12 months of right heart catheterisation (RHC). Automated ventricular segmentation and RV/LV calculation (Imbio LLC, Minneapolis, MN, USA) was undertaken on the CTPA images. PH diagnosis was made using the RHC reference standard.

Results: The automated RV/LV correlated more strongly with RHC metrics than main pulmonary artery (MPA) diameter and MPA to ascending aorta diameter ratio (MPA/AA) measured manually (mean pulmonary arterial pressure [mPAP] r=0.535, R = 0.287 p<0.001; pulmonary vascular resistance [PVR] r=0.607, R = 0.369 p<0.001). In the derivation cohort (n=100), the area under the receiver-operating curve for automated RV/LV discriminating PH was 0.752 (95% confidence interval [CI] 0.677-0.827, p<0.001). Using an optimised Youden's Index of ≥1.12 classified from derivation, automated RV/LV ratio analysis was more sensitive for the detection of PH with higher positive predictive value (PPV) when compared with manual MPA and MPA/AA in the validation cohort (n=102). Automated RV/LV compromise (1.12) and specific (1.335) thresholds were strongly predictive of mortality (log-rank 7.401, p=0.007 and log-rank 16.075, p<0.001 respectively).

Conclusion: In suspected PH, automated RV/LV diameter thresholds have high sensitivity for PH, outperform manual MPA and MPA/AA and can predict survival.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.crad.2022.03.009DOI Listing

Publication Analysis

Top Keywords

diameter ratio
12
diagnostic accuracy
8
accuracy automated
8
automated artificial
8
artificial intelligence
8
intelligence derived
8
pulmonary angiography
8
pulmonary hypertension
8
heart catheterisation
8
patients suspected
8

Similar Publications

Background: This study examines the relationship between the anterior offset of the tibial intramedullary nail (TIN) entry point and the tibial shaft axis to enhance the fit and alignment of TINs, using transparent 3D-CT in an accurate lateral view to minimize rotational artifacts.

Methods: Data were collected from 100 adult patients undergoing tibial CT scans. Measurements included the anterior offset from the tibial axis to the entry point, tibial tubercle offset, tibial plateau length, posterior slope, tibial length, isthmus diameter, and the isthmus-to-tibial length ratio.

View Article and Find Full Text PDF

Spontaneous capillary flow in rectangular microfluidic channels is employed in microfluidic devices for various applications. The exact solution for flow in a rectangular cross-sectional channel has a complex point that contains an infinite sum term. The flow depends on the depth-width ratio of the rectangular channel's cross-section, .

View Article and Find Full Text PDF

Here, a high molecular weight polysaccharide preparation from Ophiocordyceps gracilis was utilized as a stabilizer and dispersant to create nanocomposites based on selenium nanoparticles (GSP-1a-SeNPs). The NPs showed the highest stability at a selenium/polysaccharide mass ratio of 1:1, with no significant change after 28 days of storage at 4 °C. The NPs exhibited a symmetrical spheroid structure with an average diameter of 85.

View Article and Find Full Text PDF

Innovative packaging materials are essential for preserving food, serving as a substitute for petroleum-based options. In this study, biofilms consisting of pullulan and gellan gum which incorporates astaxanthin nanoemulsion were prepared to extend the shelf-life of strawberries. Hydrophobic deep eutectic solvents (DES) were used as solvents to extract natural astaxanthin from Haematococcus pluvialis.

View Article and Find Full Text PDF

Purpose: To evaluate the effects of four-dimensional noise reduction filtering using a similarity algorithm (4D-SF) on the image quality and tumor visibility of low-dose dynamic computed tomography (CT) in evaluating breast cancer.

Materials And Methods: Thirty-four patients with 38 lesions who underwent low-dose dynamic breast CT and were pathologically diagnosed with breast cancer were enrolled. Dynamic CT images were reconstructed using iterative reconstruction alone or in combination with 4D-SF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!