A method for three-dimensional reconstruction of objects from defocused images collected at multiple illumination directions in high-resolution transmission electron microscopy is presented. The method effectively corrects for the Ewald sphere curvature by taking into account the in-particle propagation of the electron beam. Numerical simulations demonstrate that the proposed method is capable of accurately reconstructing biological molecules or nanoparticles from high-resolution defocused images under conditions achievable in single-particle electron cryo-microscopy or electron tomography with realistic radiation doses, non-trivial aberrations, multiple scattering, and other experimentally relevant factors. The physics of the method is based on the well-known Diffraction Tomography formalism, but with the phase-retrieval step modified to include a conjugation of the phase (i.e., multiplication of the phase by a negative constant). At each illumination direction, numerically backpropagating the beam with the conjugated phase produces maximum contrast at the location of individual atoms in the molecule or nanoparticle. The resultant algorithm, Conjugated Holographic Reconstruction, can potentially be incorporated into established software tools for single-particle analysis, such as, for example, RELION or FREALIGN, in place of the conventional contrast transfer function correction procedure, in order to account for the Ewald sphere curvature and improve the spatial resolution of the three-dimensional reconstruction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1017/S1431927622000630 | DOI Listing |
Oral Maxillofac Surg
January 2025
Department of Oral and Maxillofacial Surgery, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
Purpose: This study aimed to clarify the applicability of smartphone-based three-dimensional (3D) surface imaging for clinical use in oral and maxillofacial surgery, comparing two smartphone-based approaches to the gold standard.
Methods: Facial surface models (SMs) were generated for 30 volunteers (15 men, 15 women) using the Vectra M5 (Canfield Scientific, USA), the TrueDepth camera of the iPhone 14 Pro (Apple Inc., USA), and the iPhone 14 Pro with photogrammetry.
Multimed Man Cardiothorac Surg
January 2025
New Cross Hospital, Royal Wolverhampton NHS Trust, Wolverhampton, United Kingdom.
Robotic-assisted thoracic surgery has become increasingly utilized in recent years. Complex lung cancer resection surgery can be performed using a robotic approach. It facilitates 3-dimentional visualization of structures, enhanced manipulation of tissues and precise movements.
View Article and Find Full Text PDFCureus
December 2024
Department of Prosthetic Dental Sciences, College of Dentistry, Jouf University, Sakaka, SAU.
Introduction: In contemporary clinical settings, three-dimensional (3D) models have become an integral component of daily practice. Photogrammetry, a novel method in clinical practice, enables the creation of precise 3D models from small objects while maintaining their original shape and size.
Aim: To evaluate the accuracy and reliability of digital models (DM) generated using photogrammetry techniques compared to traditional gypsum models (GM) and to investigate the feasibility of utilizing free software for processing and manipulating digital dental models.
Nat Struct Mol Biol
January 2025
Key Laboratory of Biomacromolecules (CAS), National Laboratory of Biomacromolecules, CAS Center for Excellence in Biomacromolecules, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China.
Many protein complexes are highly dynamic in cells; thus, characterizing their conformational changes in cells is crucial for unraveling their functions. Here, using cryo-electron microscopy, 451,700 ribosome particles from Saccharomyces cerevisiae cell lamellae were obtained to solve the 60S region to 2.9-Å resolution by in situ single-particle analysis.
View Article and Find Full Text PDFBr J Anaesth
January 2025
Department of Anaesthesiology, Perioperative and Pain Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, China.
Background: Spread of local anaesthetic solution in the paravertebral space after erector spinae plane block (ESPB) is variable. We evaluated whether paravertebral spread of local anaesthetic is affected by patient position after ESPB.
Methods: We randomised 84 patients to receive ESPB at T with a mixture of 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!