AI Article Synopsis

  • The study reports on the short-term outcomes of 55 colorectal cancer surgeries using the Senhance Digital Laparoscopy System in Japan, assessing its feasibility and safety.
  • Patients had a median age of 71, with a variety of surgical techniques used, and the procedures showed no intraoperative complications or need for blood transfusion.
  • The results indicated that the system allowed for effective surgeries, with a median postoperative hospital stay of 7 days and only two cases of significant postoperative complications.

Article Abstract

Background: The Senhance Digital Laparoscopy System (Asensus Surgical Inc, Morrisville, NC, United States), which was introduced for the first time in Japan by our hospital, is a new surgical assistive robot following the da Vinci Surgical System. We herein report the short-term outcomes of 55 colorectal cancer surgery cases using this system at our hospital to assess the feasibility and safety of our procedures.

Materials And Methods: We retrospectively reviewed the patient backgrounds and surgical outcomes of 55 patients who underwent Senhance-assisted laparoscopic colorectal cancer surgery.

Results: The median age was 71 years. There were 31 males and 24 females, and the median body mass index was 23.1 kg/m . Fifteen patients had a history of abdominal surgery. The most common surgical technique was ileocecal resection (18 cases, 32.7%), followed by high anterior resection (11 cases, 20.0%). D2 or D3 dissection was performed in each operation, and D3 dissection was performed in 41 cases (74.5%). The median operative time was 240 minutes, the median blood loss was 5 mL, there were no intraoperative complications, and there were no cases of intraoperative blood transfusion. The median postoperative hospital stay was 7 days, which was comparable to conventional laparoscopic surgery. Postoperative complications of grade 2 or higher in the Clavien-Dindo classification were observed in two cases.

Conclusion: The short-term results of 55 colorectal cancer surgery cases using the Senhance Digital Laparoscopy System were excellent and the system was introduced and surgery was safely performed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9321837PMC
http://dx.doi.org/10.1111/ases.13064DOI Listing

Publication Analysis

Top Keywords

colorectal cancer
16
cancer surgery
12
senhance digital
12
digital laparoscopy
12
laparoscopy system
12
surgery cases
8
resection cases
8
dissection performed
8
surgery
6
system
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!