Endoscopy Artefact Detection by Deep Transfer Learning of Baseline Models.

J Digit Imaging

Department of Computer Science and Information Engineering, National University of Kaohsiung, No. 700, Kaohsiung University Rd., Nan-Tzu Dist., 811, Kaohsiung, Taiwan.

Published: October 2022

To visualise the tumours inside the body on a screen, a long and thin tube is inserted with a light source and a camera at the tip to obtain video frames inside organs in endoscopy. However, multiple artefacts exist in these video frames that cause difficulty during the diagnosis of cancers. In this research, deep learning was applied to detect eight kinds of artefacts: specularity, bubbles, saturation, contrast, blood, instrument, blur, and imaging artefacts. Based on transfer learning with pre-trained parameters and fine-tuning, two state-of-the-art methods were applied for detection: faster region-based convolutional neural networks (Faster R-CNN) and EfficientDet. Experiments were implemented on the grand challenge dataset, Endoscopy Artefact Detection and Segmentation (EAD2020). To validate our approach in this study, we used phase I of 2,200 frames and phase II of 331 frames in the original training dataset with ground-truth annotations as training and testing dataset, respectively. Among the tested methods, EfficientDet-D2 achieves a score of 0.2008 (mAP[Formula: see text]0.6+mIoU[Formula: see text]0.4) on the dataset that is better than three other baselines: Faster-RCNN, YOLOv3, and RetinaNet, and competitive to the best non-baseline result scored 0.25123 on the leaderboard although our testing was on phase II of 331 frames instead of the original 200 testing frames. Without extra improvement techniques beyond basic neural networks such as test-time augmentation, we showed that a simple baseline could achieve state-of-the-art performance in detecting artefacts in endoscopy. In conclusion, we proposed the combination of EfficientDet-D2 with suitable data augmentation and pre-trained parameters during fine-tuning training to detect the artefacts in endoscopy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9582060PMC
http://dx.doi.org/10.1007/s10278-022-00627-6DOI Listing

Publication Analysis

Top Keywords

endoscopy artefact
8
artefact detection
8
transfer learning
8
video frames
8
pre-trained parameters
8
parameters fine-tuning
8
neural networks
8
phase 331
8
331 frames
8
frames original
8

Similar Publications

Background: Therapeutic modalities used in bladder lesions/neoplasms (electrocautery, fulguration, and laser) could produce morphologic alterations leading to diagnostic challenges. While often seen on histology, they can present in urine cytology as atypia or even raise the concern for malignancy. Herein, we present clinicopathologic findings of four patients with cautery artifact in urine cytology.

View Article and Find Full Text PDF

Review of Deep Learning Performance in Wireless Capsule Endoscopy Images for GI Disease Classification.

F1000Res

November 2024

School of Computing, Faculty of Science, Forestry and Technology, University of Eastern Finland, Joensuu, North Karelia, 70211, Finland.

Wireless capsule endoscopy is a non-invasive medical imaging modality used for diagnosing and monitoring digestive tract diseases. However, the analysis of images obtained from wireless capsule endoscopy is a challenging task, as the images are of low resolution and often contain a large number of artifacts. In recent years, deep learning has shown great promise in the analysis of medical images, including wireless capsule endoscopy images.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigated the effectiveness of ultrasound and CT scans for diagnosing salivary gland stones in 188 patients, with a focus on submandibular and parotid glands.
  • It found that CT scans identified some stones missed by ultrasound, and certain techniques in ultrasound can improve accuracy.
  • The research suggests avoiding CT for patients with dental work due to radiation concerns and recommends targeted ultrasound as a safer alternative.
View Article and Find Full Text PDF

Non-operating Room Anesthesia (NORA): A Comprehensive Review of Monitored Anesthesia Care.

Cureus

August 2024

Sports Medicine, Abhinav Bindra Targeting Performance, Bangalore, IND.

Monitored anesthesia care (MAC) is being increasingly employed in non-operative environments, particularly in the realms of endoscopy and magnetic resonance imaging (MRI) procedures. This in-depth analysis delves into the essential components of MAC within these specific contexts, with a primary focus on ensuring patient safety, evaluating efficacy, and assessing procedural outcomes. It is a common practice in endoscopic procedures to necessitate sedation for the purpose of alleviating discomfort and anxiety, ultimately ensuring patient cooperation and the successful completion of the procedure.

View Article and Find Full Text PDF

Colon polyps represent a common gastrointestinal form. In order to effectively treat and prevent complications arising from colon polyps, colon polypectomy has become a commonly used therapeutic approach. Accurately segmenting polyps from colonoscopy images can provide valuable information for early diagnosis and treatment.

View Article and Find Full Text PDF