A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Perioperative Vasopressors are Associated with Delayed Graft Function in Kidney Transplant Recipients in a Primarily Black and Hispanic Cohort. | LitMetric

Negative outcome studies of vasopressors in kidney transplant have not focused on patient populations that are predominantly Black or Hispanic. Project The evaluation sought to investigate the independent impact of perioperative vasopressors on postoperative renal allograft function in a sample drawn from a primarily Black and Hispanic population. Retrospective, observational, single-center evaluation of patients > 18 years old who underwent kidney transplantation comparing outcomes based on vasopressor exposure. The study included 150 patients of which 60 received vasopressors. The primary outcome differed between groups with delayed graft function occurring in 17(28%) versus 11(12.2%) occurring more often in those that received perioperative vasopressors (P = 0.02). The serum creatinine at postoperative day 7 was higher (2.69 vs1.52 mg/dL, P = 0.004), postoperative day 7 eGFR was worse (27.3 vs 52.9 mL/min/1.73m2, P = 0.002) in patients who received vasopressors. Patients who received perioperative vasopressors experienced more postoperative arrhythmias (15% vs 8%, P = 0.007), insulin infusion therapy (26.7% vs 13.3%, P = 0.04), and increased hospital length of stay (6 days vs 5 days, P = 0.006). Using IPWRA, patients receiving vasopressors were more likely to experience delayed function, relative risk difference of 22% (95% CI:0.08-0.35;P = 0.002) and in multivariate logistic regression modeling, an increased odds ratio of 3.2 (95% CI:1.1-8.62;P = 0.022). The use of perioperative vasopressors was independently associated with worsened early renal allograft function including delayed graft function, increased adverse events such as postoperative arrhythmias, and longer ICU length of stay. Further investigation is needed surrounding vasopressor use in this population.

Download full-text PDF

Source
http://dx.doi.org/10.1177/15269248221087433DOI Listing

Publication Analysis

Top Keywords

perioperative vasopressors
20
delayed graft
12
graft function
12
black hispanic
12
patients received
12
kidney transplant
8
vasopressors
8
renal allograft
8
allograft function
8
received vasopressors
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!