A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Airflow Patterns in Double-Occupancy Patient Rooms May Contribute to Roommate-to-Roommate Transmission of Severe Acute Respiratory Syndrome Coronavirus 2. | LitMetric

Background: Hospitalized patients are at risk to acquire severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from roommates with unrecognized coronavirus disease 2019 (COVID-19). We hypothesized that airflow patterns might contribute to SARS-CoV-2 transmission in double-occupancy patient rooms.

Methods: A device emitting condensed moisture was used to identify airflow patterns in double-occupancy patient rooms. Simulations were conducted to assess transfer of fluorescent microspheres, 5% sodium chloride aerosol, and aerosolized bacteriophage MS2 between patient beds 3 meters apart and to assess the effectiveness of privacy curtains and portable air cleaners in reducing transfer.

Results: Air flowed from inlet vents in the center of the room to an outlet vent near the door, resulting in air currents flowing toward the bed adjacent to the outlet vent. Fluorescent microspheres (212-250-µm diameter), 5% sodium chloride aerosol, and aerosolized bacteriophage MS2 released from the inner bed were carried on air currents toward the bed adjacent to the outlet vent. Closing curtains between the patient beds reduced transfer of each of the particles. Operation of a portable air cleaner reduced aerosol transfer to the bed adjacent to the outlet vent but did not offer a benefit over closing the curtains alone, and in some situations, resulted in an increase in aerosol exposure.

Conclusions: Airflow patterns in double-occupancy patient rooms may contribute to risk for transmission of SARS-CoV-2 between roommates. Keeping curtains closed between beds may be beneficial in reducing risk.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9129113PMC
http://dx.doi.org/10.1093/cid/ciac334DOI Listing

Publication Analysis

Top Keywords

airflow patterns
16
double-occupancy patient
16
outlet vent
16
patterns double-occupancy
12
patient rooms
12
bed adjacent
12
adjacent outlet
12
rooms contribute
8
severe acute
8
acute respiratory
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!