Purpose: To identify the effects of a single 30 min partial lower leg external pneumatic compression (EPC) treatment compared to a static compression (SC) garment or a no treatment control (CTL) on markers of recovery and performance following a muscle damaging protocol.

Methods: Thirty healthy, active males (23 ± 3 years; 180.2 ± 9.0 cm; 81.6 ± 11.3 kg) performed 100 drop jumps from a 0.6 m box followed by a randomized, single 30 min treatment of either a partial lower leg EPC device worn below the knee and above the ankle (110 mmHg), SC garment (20-30 mmHg) covering the foot and calf just below the knee, or no treatment CTL, and then returned 24 and 48 h later. Participants were assessed for measures of muscle soreness, fatigue, hemodynamics, blood lactate, muscle thickness, circumferences, and performance assessments.

Results: The drop jump protocol significantly increased muscle soreness (p < 0.001), fatigue (p < 0.001), blood flow (p < 0.001), hemoglobin (p < 0.001), and muscle oxygen saturation (SMO; p < 0.001). Countermovement jump and squat jump testing completed after treatment with either EPC, SC, or CTL revealed no differences for jump height between any condition. However, EPC treatment maintained consistent braking force and propulsive power measures across all timepoints for countermovement jump testing. EPC and SC treatment also led to better maintenance of squat jump performance for average relative propulsive force and power variables at 24 and 48 h compared to CTL.

Conclusions: A single 30 min partial leg EPC treatment may lead to more consistent jump performance following a damaging bout of exercise.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00421-022-04953-zDOI Listing

Publication Analysis

Top Keywords

external pneumatic
8
pneumatic compression
8
static compression
8
compression garment
8
single 30 min
8
partial lower
8
lower leg
8
muscle soreness
8
effects external
4
compression
4

Similar Publications

Removal of Subretinal Gas After Pneumatic Retinopexy Under Air Using External Manipulation.

Retin Cases Brief Rep

January 2025

The Retina Service of Wills Eye Hospital, Wills Eye Physicians-Mid Atlantic Retina, Thomas Jefferson University, Philadelphia, PA.

Purpose: To illustrate a technique for the removal of subretinal gas via pars plana vitrectomy (PPV) with air-fluid exchange and simultaneous manipulation with scleral depression.

Methods: PPV to remove subretinal gas causing persistent macula-off retinal detachment was performed in one eye, and the results were evaluated in this case report. Ports were carefully placed to avoid puncturing the retina, which was significantly displaced anteriorly past the ora serrata due to the buoyancy of the subretinal gas with the patient in a supine position.

View Article and Find Full Text PDF

An esophageal stent integrated with wireless battery-free movable photodynamic-therapy unit for targeted tumor treatment.

Mater Today Bio

February 2025

Department of Radiation Oncology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, 610041, China.

Article Synopsis
  • Esophageal cancer ranks as the eighth most common type of cancer globally and is the sixth leading cause of cancer-related deaths.
  • The study introduces an innovative esophageal stent that features a wireless, battery-free, movable photodynamic therapy (PDT) unit, designed for flexible and precise treatment of esophageal tumors.
  • The system integrates a light source for PDT to induce tumor cell death and an electrochemical pneumatic actuator that allows for real-time positioning of the light source, improving targeted therapy based on tumor progression.
View Article and Find Full Text PDF

An Octopus-Inspired Soft Pneumatic Robotic Arm.

Biomimetics (Basel)

December 2024

Department of Electrical and Computer Engineering, Hellenic Mediterranean University, GR-71410 Heraklion, Greece.

Article Synopsis
  • The paper discusses a soft robot arm inspired by the octopus, focusing on its design and control methods.
  • The arm, made of soft silicone, features multiple pneumatically actuated chambers that allow for versatile bending, length adjustment, and twisting motions.
  • The design includes experimental evaluation techniques that utilize visual feedback to track the arm's shape and position in real time.
View Article and Find Full Text PDF

Fragile fruit uploading and packaging are labor-intensive and time-consuming steps in postharvest industry. With the aging of the global population, it is supposed to develop robotic grasping systems to replace manual labor. However, damage-less grasping of fragile fruit is the key problem in robotization.

View Article and Find Full Text PDF
Article Synopsis
  • Metal stable isotopes are gaining popularity in fields such as planetary science and medical research, which necessitates efficient analysis methods for small and valuable samples.
  • The study presents a new, highly efficient method called microultrasonic single-droplet nebulization (MUSDN) that significantly improves sensitivity for analyzing lithium (Li) and copper (Cu) isotopes compared to traditional techniques.
  • MUSDN requires considerably less sample (1-2 ng) and is faster than conventional methods, showing excellent precision and accuracy validated against various standards and real serum samples, making it beneficial for isotope research with limited samples.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!