Based on synchronous phase shift determination, we propose a differential phase measurement method for differential interference contrast (DIC) microscopy. An on-line phase shift measurement device is used to generate carrier interferograms and determine the phase shift of DIC images. Then the differential phase can be extracted with the least-squares phase-shifting algorithm. In addition to realizing on-line, dynamic, real-time, synchronous and high precision phase shift measurement, the proposed method also can reconstruct the phase of the specimen by using the phase-integral algorithm. The differential phase measurement method reveals obvious advantages in error compensation, anti-interference, and noise suppression. Both simulation analysis and experimental result demonstrate that using the proposed method, the accuracy of phase shift measurement is higher than 0.007 rad. Very accurate phase reconstructions were obtained with both polystyrene microspheres and human vascular endothelial.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.456272DOI Listing

Publication Analysis

Top Keywords

phase shift
24
differential phase
16
phase measurement
12
shift measurement
12
phase
11
based synchronous
8
synchronous phase
8
shift determination
8
measurement method
8
proposed method
8

Similar Publications

In the last decade, substantial progress has been made to improve the performance of optical gyroscopes for inertial navigation applications in terms of critical parameters such as bias stability, scale factor stability, and angular random walk (ARW). Specifically, resonant fiber optic gyroscopes (RFOGs) have emerged as a viable alternative to widely popular interferometric fiber optic gyroscopes (IFOGs). In a conventional RFOG, a single-wavelength laser source is used to generate counter-propagating waves in a ring resonator, for which the phase difference is measured in terms of the resonant frequency shift to obtain the rotation rate.

View Article and Find Full Text PDF

The frequency diverse array (FDA) is an architecture capable of beamforming in both range and angle, improving upon the traditional phased array (PA) which can only achieve beamforming in angle. The FDA employing directional modulation (DM) for secure directional communications (SDC) can reduce bit error rates (BERs) in both range and angle, again improving upon the traditional PA which can only reduce BER in angle. In this paper, we document the challenges involved in the design and implementation of a two-element linear FDA employing fast-time binary phase-shift keying (BPSK) modulations.

View Article and Find Full Text PDF

Magnetic Induction Phase Difference for Cerebral Hemorrhage Detection.

Sensors (Basel)

December 2024

Department of Biomedical Engineering, Army Medical University, The Third Military Medical University, Chongqing 400038, China.

Magnetic induction phase shift is a promising technology for the detection of cerebral hemorrhage, owing to its nonradioactive, noninvasive, and real-time detection properties. To enhance the detection sensitivity and linearity, a zero-flow sensor was proposed. The uniform primary magnetic field and its counteraction were achieved.

View Article and Find Full Text PDF

This paper proposes and implements a novel scheme for recording signals from fibre optic sensors based on tandem low-coherence interferometry with an integrated optical reference interferometer. The circuit allows precision control of the phase shift. Additionally, the paper illustrates the potential for detecting vibration and object deformation using fibre optic Fabry-Perot sensors connected to the registration system.

View Article and Find Full Text PDF

Existing tunable optical metasurfaces based on the electro-optic effect are either complex in structure or have a limited phase modulation range. In this paper, a simple rectangular metasurface structure based on a Pb(MgNb)O-PbTiO (PMN-PT) crystal with high electro-optic coefficient of 120 pm/V was designed to demonstrate its electrically tunable performance in the optical communication band through simulations. By optimizing the structure parameters, a tunable metasurface was generated that can induce a complete 2π phase shift for beam deflection while maintaining relatively uniform transmittance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!