https://eutils.ncbi.nlm.nih.gov/entrez/eutils/efetch.fcgi?db=pubmed&id=35472113&retmode=xml&tool=Litmetric&email=readroberts32@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09https://eutils.ncbi.nlm.nih.gov/entrez/eutils/esearch.fcgi?db=pubmed&term=pull-off+force&datetype=edat&usehistory=y&retmax=5&tool=Litmetric&email=readroberts32@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09 Pull-off Force of Four Different Implant Cements Between Zirconia Crowns and Titanium Implant Abutments in Two Different Abutment Heights. | LitMetric

This study evaluated the pull-off force between titanium abutments and zirconia crowns that were bonded using four different cements and two abutment heights (AHs). In total, 24 titanium abutments (3-mm AH: n = 12; 5-mm AH: n = 12; taper: 7.5 degrees) and 24 zirconia crowns were designed, manufactured, cemented with one of four dental cements (one temporary, two semi-permanent, one permanent), stored in water for 24 hours, and thermocycled (37,500 cycles, equal to ~4 years in vivo). The pull-off force needed to separate the abutment and crown in each combination was determined eight times per combination of cement type and abutment height. Statistical analysis was conducted at a significance level of P < .05. The permanent self-adhesive composite cement showed a high pull-off force with a risk for crown fracture (mean: 381 N for 3-mm AH; 617 N for 5-mm AH). In contrast, the temporary zinc-oxide cement showed frequent premature decementation after thermocycling (mean: 14 N with 3-mm AH; 28 N with 5-mm AH). Both semi-permanent methacrylate-based cements ranked between the other cements (mean: 31 N/37 N for 3-mm AH; 120 N/72 N for 5-mm AH). Statistically significant differences were found between all cements (ANOVA P < .001). The abutment heights differed significantly for all cements (P < .005) except for the temporary zinc-oxide cement. Methacrylate-based cements were the most reliable cements for semi-permanent mounting of zirconia crowns on titanium abutments. They provide sufficient retention to avoid unintended loosening and are weak enough to remove the crown without causing damage.

Download full-text PDF

Source
http://dx.doi.org/10.11607/prd.4926DOI Listing

Publication Analysis

Top Keywords

pull-off force
16
zirconia crowns
16
abutment heights
12
titanium abutments
12
cements
9
crowns titanium
8
3-mm 5-mm
8
temporary zinc-oxide
8
zinc-oxide cement
8
methacrylate-based cements
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!