In vivo stiffness measurement of epidermis, dermis, and hypodermis using broadband Rayleigh-wave optical coherence elastography.

Acta Biomater

Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, United States; Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139, United States; Department of Dermatology, Massachusetts General Hospital, Boston, MA 02114, United States. Electronic address:

Published: July 2022

Traveling-wave optical coherence elastography (OCE) is a promising technique to measure the stiffness of biological tissues. While OCE has been applied to relatively homogeneous samples, tissues with significantly varying elasticity through depth pose a challenge, requiring depth-resolved measurement with sufficient resolution and accuracy. Here, we develop a broadband Rayleigh-wave OCE technique capable of measuring the elastic moduli of the 3 major skin layers (epidermis, dermis, and hypodermis) reliably by analyzing the dispersion of leaky Rayleigh surface waves over a wide frequency range of 0.1-10 kHz. We show that a previously unexplored, high frequency range of 4-10 kHz is critical to resolve the thin epidermis, while a low frequency range of 0.2-1 kHz is adequate to probe the dermis and deeper hypodermis. We develop a dual bilayer-based inverse model to determine the elastic moduli in all 3 layers and verify its high accuracy with finite element analysis and skin-mimicking phantoms. Finally, the technique is applied to measure the forearm skin of healthy volunteers. The Young's modulus of the epidermis (including the stratum corneum) is measured to be ∼ 4 MPa at 4-10 kHz, whereas Young's moduli of the dermis and hypodermis are about 40 and 15 kPa, respectively, at 0.2-1 kHz. Besides dermatologic applications, this method may be useful for the mechanical analysis of various other layered tissues with sub-mm depth resolution. STATEMENT OF SIGNIFICANCE: To our knowledge, this is the first study that resolves the stiffness of the thin epidermis from the dermis and hypodermis, made possible by using high-frequency (4 - 10 kHz) elastic waves and optical coherence elastography. Beyond the skin, this technique may be useful for mechanical characterizations of various layered biomaterials and tissues.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.actbio.2022.04.030DOI Listing

Publication Analysis

Top Keywords

dermis hypodermis
16
epidermis dermis
12
optical coherence
12
coherence elastography
12
frequency range
12
broadband rayleigh-wave
8
elastic moduli
8
thin epidermis
8
epidermis
5
dermis
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!