A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optimization of an rGO-based biosensor for the sensitive detection of bovine serum albumin: Effect of electric field on detection capability. | LitMetric

Optimization of an rGO-based biosensor for the sensitive detection of bovine serum albumin: Effect of electric field on detection capability.

Chemosphere

Center for Membranes and Advanced Water Technology (CMAT), Khalifa University of Science and Technology, PO Box 127788, Abu Dhabi, United Arab Emirates; Department of Chemical Engineering, Khalifa University of Science and Technology, PO Box 127788, Abu Dhabi, United Arab Emirates. Electronic address:

Published: August 2022

Despite significant progress in the field of biosensing, the impact of electric field on biosensor detection capability and the feasibility of the biosensor application in wastewater has yet to be investigated. The objective of this study was to develop a low-cost, highly sensitive, and selective reduced graphene oxide (rGO)-based biosensor. The constructed biosensor consists of an in-house prepared GO and a four-terminal Kelvin sensing. Spin-coating was chosen as the deposition technique and results revealed an optimal GO number of layers and concentration of 7 and 2 mg/mL, respectively. Experiments to determine the effects of electric field on the performance of the biosensor showed significant changes in the biosensor surface, also presenting a direct impact on the biosensor functionality, such that the biosensor showed an increase in limit of detection (LOD) from 1 to 10 fg/mL when the applied voltage was increased from 0.0008 to 0.2 V. Furthermore, this study successfully explores a pilot scale setup, mimicking wastewater flow through sewage pipelines. The demonstrated improvements in the detection capability and sensitivity of this biosensor at optimized testing conditions make it a promising candidate for further development and deployment for the detection of protein analytes present at very low concentrations in aqueous solutions. In addition, the application of this biosensor could be extended to the detection of protein analytes of interest (such as the spike protein of SARS-CoV-2) in much more complex solutions, like wastewater.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chemosphere.2022.134700DOI Listing

Publication Analysis

Top Keywords

electric field
12
detection capability
12
biosensor
11
rgo-based biosensor
8
detection protein
8
protein analytes
8
detection
7
optimization rgo-based
4
biosensor sensitive
4
sensitive detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!