Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: The aim of this study was to screen practices used in verification procedures for methods/analysers among medical biochemistry laboratories (MBLs) in Croatia. We hypothesized that these procedures differ widely from laboratory to laboratory and wanted to gather specific data on steps used in the verification workflow.
Materials And Methods: In order to obtain data, an online survey was conducted. The survey, divided in two sections, contained 29 questions and statements addressing general characteristics and specific steps of the verification workflow of each individual MBL. The survey was disseminated among managers of all MBLs in Croatia.
Results: A total of 108/196 (55%) laboratories participated in the survey. Forty nine MBLs were excluded from the second part of the survey: 14 have not implemented verification procedures, and 35 MBLs due to the absence of answers. The most relevant results of the second part of the survey showed that: 18/59 (0.31) of the responding MBLs have difficulties when defining acceptance criteria, 27/59 (0.46) used the Clinical and Laboratory Standards Institute protocol for precision estimation; the majority of MBLs used a median of 20 samples for method/analyser comparisons and estimated bias using internal quality control samples; reference intervals provided by external sources are mainly adopted; 60% of MBLs do not include linearity verification in their protocol and do not use the national document for the estimation of measurement uncertainty.
Conclusions: Heterogeneous verification protocols are routinely utilized across Croatian MBLs which clearly confirms that a national document might help in the harmonization of verification procedures.