AI Article Synopsis

  • The study aimed to assess how changes in physical activity (PA) after implantable heart devices affect long-term health outcomes, focusing on mortality rates.
  • Analyzing data from 705 patients, it found that 63.3% experienced improved PA within a year, which correlated with notably lower risks of cardiac death and overall mortality.
  • The findings suggest that enhancing physical activity, even minimally, may lead to better health outcomes after implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) procedures, especially for patients with varying initial PA levels.

Article Abstract

Objective: To evaluate the association of longitudinal changes in physical activity (PA) with long-term outcomes after implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) implantation.

Methods: Patients with ICD/CRT-D implantation from SUMMIT registry were retrospectively analyzed. Accelerometer-derived PA changes over 12 months post implantation were obtained from the archived home monitoring data. The primary endpoints were cardiac death and all-cause mortality. The secondary endpoints were the first ventricular arrthymia (VA) and first appropriate ICD shock.

Results: In 705 patients, 446 (63.3%) patients showed improved PA over 12 months after implantation. During a mean 61.5-month follow-up duration, 99 cardiac deaths (14.0%) and 153 all-cause deaths (21.7%) occurred. Compared to reduced/unchanged PA, improved PA over 12 months could result in significantly reduced risks of cardiac death (improved PA ≤ 30 min: hazard ratio (HR) = 0.494, 95% CI: 0.288-0.848; > 30 min: HR = 0.390, 95% CI: 0.235-0.648) and all-cause mortality (improved PA ≤ 30 min: HR = 0.467, 95%CI: 0.299-0.728; > 30 min: HR = 0.451, 95% CI: 0.304-0.669). No differences in the VAs or ICD shocks were observed across different groups of PA changes. PA changes can predict the risks of cardiac death only in the low baseline PA group, but improved PA was associated with 56.7%, 57.4%, and 62.3% reduced risks of all-cause mortality in the low, moderate, and high baseline PA groups, respectively, than reduced/unchanged PA.

Conclusions: Improved PA could protect aganist cardiac death and all-cause mortality, probably reflecting better clinical efficacy after ICD/CRT-D implantation. Low-intensity exercise training might be encouraged among patients with different baseline PA levels.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9002081PMC
http://dx.doi.org/10.11909/j.issn.1671-5411.2022.03.006DOI Listing

Publication Analysis

Top Keywords

cardiac death
20
all-cause mortality
20
death all-cause
12
changes physical
8
physical activity
8
icd/crt-d implantation
8
improved months
8
reduced risks
8
risks cardiac
8
improved ≤
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!