Glucometer is the most commonly used POCT device and guides monitoring of blood glucose level in both clinical settings and outside. Inaccurate glucometer readings resulting in erroneous therapeutic intervention has critical consequences on patient care. Regulatory guidelines for performance evaluation of glucometers are not available in many countries. A robust program implemented by the hospital is essential to ensure accuracy and precision of glucometers to produce optimal results. The objective of this study was to design a quality assurance program for the evaluation of glucometers in a high volume tertiary care referral hospital and evaluate the results from July'18 to July'19. Seventy three glucometers used across the hospital were subjected to Internal Quality Control checks and Proficiency Testing performed once a month and every 3 months respectively. The results were reviewed and plotted on a Bland Altman Graph. Clarke Error Grid Analysis was done to evaluate the clinical significance of inaccuracies in the measurement of blood glucose concentration as per ISO 15197: 2013. Eight devices were identified as unacceptable by ISO standards and replaced subsequently. 96.83% and 3.17% of the values were in Zone A and B of Clarke Error Grid Analysis. The study complied with the standard which requires that 99% of the values fall within zones A and B. The review of the program after one year and its ability to identify defective glucometers has validated the efficacy of the model. The method used may be suggested as a prototype for quality management of glucometers in a clinical setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8993970PMC
http://dx.doi.org/10.1007/s12291-021-00971-4DOI Listing

Publication Analysis

Top Keywords

clarke error
12
error grid
12
grid analysis
12
evaluation glucometers
12
performance evaluation
8
tertiary care
8
care referral
8
referral hospital
8
blood glucose
8
glucometers
7

Similar Publications

Evaluation of Non-Invasive Hemoglobin Monitoring in Perioperative Patients: A Retrospective Study of the Rad-67 (Masimo).

Diagnostics (Basel)

January 2025

Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.

: Hemoglobin (Hb) is a crucial parameter in perioperative care due to its essential role for oxygen transport and tissue oxygenation. Accurate Hb monitoring allows for timely interventions to address perioperative anemia and, thus, prevent morbidity and mortality. Traditional Hb measurements rely on invasive blood sampling, which significantly contributes to iatrogenic anemia and poses discomfort and increased infection risks.

View Article and Find Full Text PDF

Background: Perception-related errors comprise most diagnostic mistakes in radiology. To mitigate this problem, radiologists use personalized and high-dimensional visual search strategies, otherwise known as search patterns. Qualitative descriptions of these search patterns, which involve the physician verbalizing or annotating the order he or she analyzes the image, can be unreliable due to discrepancies in what is reported versus the actual visual patterns.

View Article and Find Full Text PDF

Homologous recombination (HR) is important for DNA damage tolerance during replication. The yeast Shu complex, a conserved homologous recombination factor, prevents replication-associated mutagenesis. Here we examine how yeast cells require the Shu complex for coping with MMS-induced lesions during DNA replication.

View Article and Find Full Text PDF

Background: Hyperglycemia is an independent risk factor for perioperative complications and mortality after cardiac surgery. Freestyle Libre Continuous glucose monitor (CGM) is an interstitial glucose monitoring system, which has been proven to be stable and accurate in various disease.

Materials And Methods: 86 patients with hyperglycemia after cardiac surgery between October 2021 and October 2022 in the cardiovascular ICU, were enrolled in this study.

View Article and Find Full Text PDF

Wingbeat frequency estimation is an important aspect for the study of avian flight, energetics, and behavioral patterns, among others. Hummingbirds, in particular, are ideal subjects to test a method for this estimation due to their fast wing motions and unique aerodynamics, which results from their ecological diversification, adaptation to high-altitude environments, and sexually selected displays. Traditionally, wingbeat frequency measurements have been done via "manual" image/sound processing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!