Reliability and Safety of Individualized Follow-up Based on the 30-day Computed Tomography Angiogram after Endovascular Aneurysm Repair.

Ann Vasc Surg

Centre for Vascular Surgery and Interventional Radiology, Tampere University Hospital, and Tampere University, Faculty of Medicine and Life Sciences, Tampere, Finland.

Published: October 2022

Background: Most patients undergo uneventful surveillance after endovascular aneurysm repair (EVAR), and therefore, unmodified surveillance protocols are ineffective. An example of a modified follow-up protocol was introduced by the European Society for Vascular Surgery (ESVS) in January 2019. One feature of this protocol is that for the patients with adequate sealing and without any detectable endoleak at 30 days, the next scheduled follow-up could be at 5 years. The purpose of this study was to analyze retrospectively the applicability of this protocol.

Methods: Between 2005 and 2013, 348 patients were treated electively for abdominal aortic aneurysm (AAA) with a standard EVAR. All patients were annually followed and they were retrospectively fitted into the ESVS follow-up protocol based on imaging findings.

Results: The mean follow-up was 74 months (standard error 2.1; range, 0-165 months). Thirty-day mortality was 1.1% (n = 4). Imaging data for those surviving the first 30 days were available for 98.8% (n = 340) subjects. At a 1-month control examination, 79.3% (n = 276) of the patients had no detectable endoleak and sealing was adequate (≥1 cm). Of those patients, with the lowest risk, 11.6% (n = 32) required reintervention for graft-related complication during the next 5 years. In all, complications requiring treatment that would have been missed by following the suggested protocol included type 1A endoleak (n = 7), type 1B (n = 10), type 2 (n = 7), migration (n = 2), thrombosis (n = 10), kinking (n = 1), and ruptured AAA (n = 6). The sensitivity of 30-day computed tomography angiogram was 34.9% (95% confidence interval 21.01-50.93%) and specificity 83.3% (95% confidence interval 78.57-87.41%) for finding significant complications during first 5 years.

Conclusions: Based on our findings, by following the example ESVS follow-up protocol, we would have missed major life-threatening complications. Significant stent-graft failures occur during the first 5 years, even for those with noncomplicated post-EVAR findings in the first computed tomography angiogram at 1 month.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.avsg.2022.04.014DOI Listing

Publication Analysis

Top Keywords

computed tomography
12
tomography angiogram
12
follow-up protocol
12
30-day computed
8
endovascular aneurysm
8
aneurysm repair
8
detectable endoleak
8
esvs follow-up
8
95% confidence
8
confidence interval
8

Similar Publications

The goal of this study was to determine how radiologists' rating of image quality when using 0.5T Magnetic Resonance Imaging (MRI) compares to Computed Tomography (CT) for visualization of pathology and evaluation of specific anatomic regions within the paranasal sinuses. 42 patients with clinical CT scans opted to have a 0.

View Article and Find Full Text PDF

Body composition abnormalities are prognostic markers in several types of cancer, including colorectal cancer (CRC). Using our data distribution on body composition assessments and classifications could improve clinical evaluations and support population-specific opportune interventions. This study aimed to evaluate the distribution of body composition from computed tomography and assess the associations with overall survival among patients with CRC.

View Article and Find Full Text PDF

Engineering plastics are finding widespread applications across a broad temperature spectrum, with additive manufacturing (AM) having now become commonplace for producing aerospace-grade components from polymers. However, there is limited data available on the behavior of plastic AM parts exposed to elevated temperatures. This study focuses on investigating the tensile strength, tensile modulus and Poisson's ratio of parts manufactured using fused filament fabrication (FFF) and polyetheretherketone (PEEK) plastics doped with two additives: short carbon fibers (SCFs) and multi-wall carbon nanotubes (MWCNTs).

View Article and Find Full Text PDF

The position of the mental foramen is reported to change with age. This study aimed to examine age-related changes in the position of the mental foramen in men and women. Among 200 cases (age 21-100 years; 400 foramina) that underwent postmortem computed tomography, 109 (age 21-93 years; 218 foramina) with mandibular first and second premolars were examined using image analysis software to classify the position of the mental foramen according to Fishel's classification, and the χ² test was performed.

View Article and Find Full Text PDF

Diagnostic criteria for temporomandibular joint osteoarthritis using standardized uptake value in single-photon emission computed tomography-computed tomography.

Sci Rep

December 2024

Department of Oral and Maxillofacial Surgery, Yonsei University College of Dentistry, Gangnam Severance Hospital, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Republic of Korea.

This study aimed to investigate the cutoff values of standardized uptake values (SUVs) and their accuracy using single-photon emission computed tomography-computed tomography (SPECT-CT) for temporomandibular joint (TMJ) osteoarthritis (OA) based on magnetic resonance imaging (MRI) and clinical examination. We included 106 joints of 53 patients with TMJ OA. SUVmax and SUVpeak of each TMJ was measured.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!