Scaphoid Fracture Detection by Using Convolutional Neural Network.

Diagnostics (Basel)

Department of Computer Science and Information Engineering, National Cheng Kung University, Tainan 701, Taiwan.

Published: April 2022

AI Article Synopsis

  • - Scaphoid fractures are often hard to detect on X-rays, with about 20% being hidden or "occult," and traditional image processing methods require a lot of manual work and computing time.
  • - This study introduces a two-stage convolutional neural network model to better identify and classify scaphoid fractures in X-ray images, using advanced techniques like Faster R-CNN for bone separation and ResNet for feature extraction.
  • - The results showed high accuracy in detecting scaphoid bones (99.70%) and solid performance metrics for fracture detection and classification, indicating that this approach could significantly improve the detection process for scaphoid fractures in the future.

Article Abstract

Scaphoid fractures frequently appear in injury radiograph, but approximately 20% are occult. While there are few studies in the fracture detection of X-ray scaphoid images, their effectiveness is insignificant in detecting the scaphoid fractures. Traditional image processing technology had been applied to segment interesting areas of X-ray images, but it always suffered from the requirements of manual intervention and a large amount of computational time. To date, the models of convolutional neural networks have been widely applied to medical image recognition; thus, this study proposed a two-stage convolutional neural network to detect scaphoid fractures. In the first stage, the scaphoid bone is separated from the X-ray image using the Faster R-CNN network. The second stage uses the ResNet model as the backbone for feature extraction, and uses the feature pyramid network and the convolutional block attention module to develop the detection and classification models for scaphoid fractures. Various metrics such as recall, precision, sensitivity, specificity, accuracy, and the area under the receiver operating characteristic curve (AUC) are used to evaluate our proposed method's performance. The scaphoid bone detection achieved an accuracy of 99.70%. The results of scaphoid fracture detection with the rotational bounding box revealed a recall of 0.789, precision of 0.894, accuracy of 0.853, sensitivity of 0.789, specificity of 0.90, and AUC of 0.920. The resulting scaphoid fracture classification had the following performances: recall of 0.735, precision of 0.898, accuracy of 0.829, sensitivity of 0.735, specificity of 0.920, and AUC of 0.917. According to the experimental results, we found that the proposed method can provide effective references for measuring scaphoid fractures. It has a high potential to consider the solution of detection of scaphoid fractures. In the future, the integration of images of the anterior-posterior and lateral views of each participant to develop more powerful convolutional neural networks for fracture detection by X-ray radiograph is probably important to research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9024757PMC
http://dx.doi.org/10.3390/diagnostics12040895DOI Listing

Publication Analysis

Top Keywords

scaphoid fractures
24
fracture detection
16
convolutional neural
16
scaphoid
12
scaphoid fracture
12
neural network
8
detection x-ray
8
neural networks
8
scaphoid bone
8
detection
7

Similar Publications

Objectives: The scaphoid fat pad stripe (SFS) is a radiological sign first described in 1975 as a line of relative lucency lying parallel to the lateral border of the scaphoid, with slight convexity toward it, and it is optimally demonstrated on postero-anterior and oblique views with ulnar deviation of the carpus. The obliteration or displacement of this line is commonly present in acute fractures of the scaphoid, radial styloid process, and proximal first metacarpus. The aim of this observational study is to investigate the supportive value of the fat stripe sign (SFS) in the diagnosis of scaphoid fractures in the pediatric population.

View Article and Find Full Text PDF

We compared the outcomes of two groups of patients with scaphoid nonunion treated with arthroscopic cancellous bone grafting. In group 1, K-wires were introduced beforehand and in group 2 after debridement and packing bone grafts in the nonunion site. Our hypothesis was that the percentage of unions would be higher in group 2.

View Article and Find Full Text PDF

Artificial intelligence and machine learning capabilities in the detection of acute scaphoid fracture: a critical review.

J Hand Surg Eur Vol

January 2025

Clinical Scientific Computing, Guy's and St Thomas' NHS Foundation Trust, London, UK.

This paper discusses the current literature surrounding the potential use of artificial intelligence and machine learning models in the diagnosis of acute obvious and occult scaphoid fractures. Current studies have notable methodological flaws and are at high risk of bias, precluding meaningful comparisons with clinician performance (the current reference standard). Specific areas should be addressed in future studies to help advance the meaningful and clinical use of artificial intelligence for radiograph interpretation.

View Article and Find Full Text PDF

Scapho-metacarpal dual mobility prosthesis for TMC-1 joint salvage: technical insights.

Arch Orthop Trauma Surg

January 2025

BG Klinikum Unfallkrankenhaus Berlin, Department of Hand-, Replantation- and Microsurgery and Chair of Hand-, Replantation- and Microsurgery, Charité Universitätsmedizin Berlin, Berlin, Germany.

Introduction: Rhizarthrosis, or osteoarthritis of the trapeziometacarpal joint, predominantly affects women over 50, with up to 30% experiencing some degree of arthritis in this joint. Traditional surgical approaches, such as trapeziectomy with ligament reconstruction, can result in some patients in persistent pain or limited functionality. TMC ball-in-socket arthroplasty, with a cup placed in the distal scaphoid, offers a promising alternative to traditional arthrodesis or resection-suspension arthroplasty.

View Article and Find Full Text PDF

Purpose: To evaluate the rate of missed scaphoid fractures on follow-up computed tomography (CT) for suspected occult scaphoid fracture after normal radiography with residual radial-sided wrist pain.

Methods: In a retrospective analysis, wrist CT during a five-year period was analyzed. The CT examinations and radiological reports were re-evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!