Early and accurate prediction of endotracheal tube (ETT) location is pivotal for critically ill patients. Automatic and timely detection of faulty ETT locations from chest X-ray images may avert patients' morbidity and mortality. Therefore, we designed convolutional neural network (CNN)-based algorithms to evaluate ETT position appropriateness relative to four detected key points, including tracheal tube end, carina, and left/right clavicular heads on chest radiographs. We estimated distances from the tube end to tracheal carina and the midpoint of clavicular heads. A DenseNet121 encoder transformed images into embedding features, and a CNN-based decoder generated the probability distributions. Based on four sets of tube-to-carina distance-dependent parameters (i.e., (i) 30-70 mm, (ii) 30-60 mm, (iii) 20-60 mm, and (iv) 20-55 mm), corresponding models were generated, and their accuracy was evaluated through the predicted L1 distance to ground-truth coordinates. Based on tube-to-carina and tube-to-clavicle distances, the highest sensitivity, and specificity of 92.85% and 84.62% respectively, were revealed for 20-55 mm. This implies that tube-to-carina distance between 20 and 55 mm is optimal for an AI-based key point appropriateness detection system and is empirically comparable to physicians' consensus.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9027916 | PMC |
http://dx.doi.org/10.3390/biology11040490 | DOI Listing |
J Cardiothorac Surg
January 2025
Department of Anesthesiology, Kafkas University Medical Faculty, Kars, Turkey.
Abstarct: BACKGROUND: The optimal positioned double-lumen endotracheal tubes (DLT) is crucial in thoracic surgery requiring lung isolation. This study aims to compare the accuracy and complication rates of DLT placement using videolaryngoscopy (VL) versus conventional direct laryngoscopy (DL).
Methods: This retrospective single-center study included 89 patients who underwent thoracic surgery with DLT placement between July 2023 and May 2024.
Cureus
December 2024
Department of Pediatrics, Sapporo Medical University School of Medicine, Sapporo, JPN.
Lip ulcers associated with endotracheal tube fixation are a known complication in adults, but their prevalence in neonates and preterm infants remains unclear. We report a case of a right oral commissure ulcer that developed during endotracheal tube fixation at the right oral commissure and left lateral decubitus positioning in an extremely preterm infant with unilateral pulmonary interstitial emphysema (PIE). A male infant was born at 24 weeks and four days of gestation, weighing 696 gm.
View Article and Find Full Text PDFComput Inform Nurs
January 2025
Author Affiliations: Department of Nursing, Ordu University Faculty of Health Sciences, Ordu, Turkey (Asst Prof Dr Kalkan Ugurlu and Assoc Prof Dr Durgun and Prof Dr Kucuk Alemdar).
This descriptive study aims to investigate the content, quality, and reliability of YouTube videos containing content related to endotracheal tube aspiration. The study was scanned using the keywords "endotracheal aspiration" and "endotracheal tube aspiration," and 22 videos were included in the study. The contents of the selected videos were measured using the Endotracheal Tube Aspiration Skill Form, their reliability was measured using the DISCERN Survey, and their quality was measured using the Global Quality Scale.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Korea.
Background: Monitoring core temperature is important for patients under anesthesia. Esophageal and pulmonary artery blood temperatures can be used for measuring core temperature during general anesthesia. However, these methods pose challenges, especially when the placement of an esophageal thermometer and pulmonary artery catheter (PAC) is either impractical or not the preferred approach.
View Article and Find Full Text PDFCase Rep Dent
December 2024
Department of Maxillofacial Surgery, Azienda Ospedaliera Papa Giovanni XXIII, Bergamo, Bergamo, Italy.
The authors present two cases of mouth floor hemorrhage consequences of implant placement within the atrophic anterior mandible. In one patient, the implant placement was associated with the guided bone regeneration (GBR) technique. This serious complication has been widely described in the literature, especially in the anterior mandible area.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!