Testing surfaces in school classrooms for the presence of SARS-CoV-2, the virus that causes COVID-19, can provide public-health information that complements clinical testing. We monitored the presence of SARS-CoV-2 RNA in five schools (96 classrooms) in Davis, California (USA) by collecting weekly surface-swab samples from classroom floors and/or portable high-efficiency particulate air (HEPA) units (n = 2,341 swabs). Twenty-two surfaces tested positive, with qPCR cycle threshold (Ct) values ranging from 36.07-38.01. Intermittent repeated positives in a single room were observed for both floor and HEPA filter samples for up to 52 days, even following regular cleaning and HEPA filter replacement after a positive result. We compared the two environmental sampling strategies by testing one floor and two HEPA filter samples in 57 classrooms at Schools D and E. HEPA filter sampling yielded 3.02% and 0.41% positivity rates per filter sample collected for Schools D and E, respectively, while floor sampling yielded 0.48% and 0% positivity rates. Our results indicate that HEPA filter swabs are more sensitive than floor swabs at detecting SARS-CoV-2 RNA in interior spaces. During the study, all schools were offered weekly free COVID-19 clinical testing through Healthy Davis Together (HDT). HDT also offered on-site clinical testing in Schools D and E, and upticks in testing participation were observed following a confirmed positive environmental sample. However, no confirmed COVID-19 cases were identified among students associated with classrooms yielding positive environmental samples. The positive samples detected in this study appeared to contain relic viral RNA from individuals infected before the monitoring program started and/or RNA transported into classrooms via fomites. High-Ct positive results from environmental swabs detected in the absence of known active infections supports this conclusion. Additional research is needed to differentiate between fresh and relic SARS-CoV-2 RNA in environmental samples and to determine what types of results should trigger interventions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9032406 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0267212 | PLOS |
J Expo Sci Environ Epidemiol
January 2025
Department of Environmental and Occupational Health, Joe C. Wen School of Population & Public Health, University of California, Irvine, CA, USA.
Background: Children living in communities with lower socioeconomic status and higher minority populations are often disproportionately exposed to particulate matter (PM) compared to children living in other communities.
Objective: We assessed whether adding HEPA filter air cleaners to classrooms with existing HVAC systems reduces indoor air pollution exposure.
Methods: From July 2022 to June 2023, using a block randomized crossover trial of 17 Los Angeles Unified School District elementary schools, classroom PM concentrations were monitored and compared for 99 classrooms with HEPA filter air cleaners and 87 classrooms with non-HEPA filter air cleaners.
BMJ Open
December 2024
Biological and Biomedical Sciences, The Aga Khan University, Karachi, Pakistan.
Introduction: Asthma has been classified as a major non-communicable disease by the WHO. With the worsening air quality index worldwide, the burden of asthma has increased specifically in children. The focus of the management strategy of asthma has shifted from traditional pharmacological treatments towards non-pharmacological preventive and control therapy in recent decades.
View Article and Find Full Text PDFRegen Ther
March 2025
Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan.
Introduction: The manufacture of cell-based products requires assuring sterility through all processes, with aseptic processing in a cleanroom. The environment consists of a critical processing zone (CPZ) that can ensure a level of cleanliness that allows cell culture containers to be opened, and a support zone (SZ) adjacent to it and accessed by an operator. In this study, an environment for cell manufacturing was proposed by designing an air mass balance in an aseptic processing area (APA).
View Article and Find Full Text PDFRegen Ther
June 2024
Center for Stem Cell and Regenerative Medicine, Institute of Science Tokyo, 1-5-45, Bunkyo-ku, Yushima, Tokyo 113-8519, Japan.
Introduction: Cell processing facilities are susceptible to environmental bacteria and must maintain sterile environments to safeguard cell products. This process involves circulating air through high-efficiency particulate air (HEPA) filters, which incurs significant maintenance costs. While cost-reduction strategies have been explored in the semiconductor industry, validations specific to cell processing facilities remain unreported.
View Article and Find Full Text PDFPart Fibre Toxicol
December 2024
Centre for Environmental Sciences, Hasselt University, Agoralaan gebouw D, Diepenbeek, BE-3590, Belgium.
The effects of ultrafine particle (UFP) inhalation on neurodevelopment, especially during critical windows of early life, remain largely unexplored. The specific time windows during which exposure to UFP might be the most detrimental remain poorly understood. Here, we studied early-life exposure to clean ultrafine carbonaceous particles (UFP) and neurodevelopment and central nervous system function in offspring.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!