Purpose: To evaluate immediate loss of reduction in patients undergoing hardware removal after arthroscopically assisted acromioclavicular (AC) joint stabilization using a high-tensile suture tape suspensory fixation system and to identify risk factors associated with immediate loss of reduction.

Materials And Methods: Twenty-two consecutive patients with a mean age of 36.4 ± 12.6 years (19-56), who underwent hardware removal 18.2 ± 15.0 months following arthroscopically assisted stabilization surgery using a suspensory fixation system for AC joint injury between 01/2012 and 01/2021 were enrolled in this retrospective monocentric study. The coracoclavicular distance (CCD) as well as the clavicular dislocation/acromial thickness (D/A) ratio were measured on anterior-posterior radiographs prior to hardware removal and immediately postoperatively by two independent raters. Loss of reduction, defined as 10% increase in the CCD, was deemed substantial if the CCD increased 6 mm compared to preoperatively. Constitutional and surgical characteristics were assessed in a subgroup analysis to detect risk factors associated with loss of reduction.

Results: Postoperatively, the CCD significantly increased from 12.6 ± 3.7 mm (4.8-19.0) to 14.5 ± 3.3 mm (8.7-20.6 mm) (p < 0.001) while the D/A ratio increased from 0.4 ± 0.3 (- 0.4-0.9) to 0.6 ± 0.3 (1.1-0.1) (p = 0.034) compared to preoperatively. In 10 cases (45%), loss of reduction was identified, while a substantial loss of reduction (> 6 mm) was only observed in one patient (4.5%). A shorter time interval between index stabilization surgery and hardware removal significantly corresponded to immediate loss of reduction (11.0 ± 5.6 vs. 30.0 ± 20.8 months; p = 0.007), as hardware removal within one year following index stabilization was significantly associated with immediate loss of reduction (p = 0.027; relative risk 3.4; odds ratio 11.67).

Conclusions: Substantial loss of reduction after hardware removal of a high-tensile suture tape suspensory fixation system was rare, indicating that the postoperative result of AC stabilization is not categorically at risk when performing this procedure. Even though radiological assessment of the patients showed a statistically significant immediate superior clavicular displacement after this rarely required procedure, with an increased incidence in the first year following stabilization, this may not negatively influence the results of ACJ stabilization in a clinically relevant way.

Level Of Evidence: IV.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9568474PMC
http://dx.doi.org/10.1007/s00167-022-06978-5DOI Listing

Publication Analysis

Top Keywords

hardware removal
28
loss reduction
24
suspensory fixation
16
fixation system
16
associated loss
12
loss
8
substantial loss
8
reduction hardware
8
acromioclavicular joint
8
stabilization
8

Similar Publications

Posttraining Network Compression for 3D Medical Image Segmentation: Reducing Computational Efforts via Tucker Decomposition.

Radiol Artif Intell

January 2025

From the Department of Radiology, University Hospital, LMU Munich, Marchioninistr 15,81377 Munich, Germany (T.W., J.D., M.I.); Department of Statistics, LMU Munich, Munich, Germany (T.W., D.R.); and Munich Center for Machine Learning, Munich, Germany (T.W., J.D., D.R., M.I.).

Purpose To investigate whether the computational effort of 3D CT-based multiorgan segmentation with TotalSegmentator can be reduced via Tucker decomposition-based network compression. Materials and Methods In this retrospective study, Tucker decomposition was applied to the convolutional kernels of the TotalSegmentator model, an nnU-Net model trained on a comprehensive CT dataset for automatic segmentation of 117 anatomic structures. The proposed approach reduced the floating-point operations (FLOPs) and memory required during inference, offering an adjustable trade-off between computational efficiency and segmentation quality.

View Article and Find Full Text PDF

Background: Bicondylar tibial plateau fractures are often associated with significant soft tissue compromise making operative treatment challenging. Dual plating through a two-incision approach following temporary external fixation has been shown to improve complication rates although deep infection rates remain high.The objective was to evaluate early outcomes following a novel technique of percutaneous application of the medial plate superficial to the pes anserinus tendons.

View Article and Find Full Text PDF

Multifunctional hardware technologies for neuromorphic computing are essential for replicating the complexity of biological neural systems, thereby improving the performance of artificial synapses and neurons. Integrating ionic and spintronic technologies offers new degrees of freedom to modulate synaptic potentiation and depression, introducing novel magnetic functionalities alongside the established ionic analogue behavior. We demonstrate that magneto-ionic devices can perform as synaptic elements with dynamically tunable depression linearity controlled by an external magnetic field, a functionality reminiscent of neuromodulation in biological systems.

View Article and Find Full Text PDF

Paraspinal hematomas are common complications following spine surgery. In general, these hematomas are asymptomatic and resolve without issue. Unfortunately, there is a paucity of literature that describes the recurrence of these hematomas in a chronic setting.

View Article and Find Full Text PDF

The traditional standard of care, tension band wire fixation modalities commonly used to treat non-comminuted olecranon fractures, are frequently associated with complications, with symptomatic hardware being the most common issue, often necessitating subsequent surgical procedures for hardware removal. We present a case of a young, active gentleman who sustained a simple olecranon fracture (Mayo type IIA) and underwent open reduction with the innovative all-suture non-metallic internal fixation procedure. We used a low-profile, cost-effective alternative fracture fixation technique, following the principles of pre-existing surgical techniques, while utilizing FiberWire sutures with biomechanical properties equivalent to, or possibly superior to, conventionally used metallic wires, thereby eliminating the need for additional surgical intervention.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!