A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of ultrasound and dorsal tangential view for dorsal cortex screw penetration in volar plating of the distal radius. | LitMetric

We compared the accuracy of the fluoroscopic dorsal tangential view (DTV) and an ultrasound (US) examination in detecting dorsal screw penetration during volar distal radius plating. In six fresh cadaveric distal radii, seven periarticular locking screws in two rows for each plate were inserted according to the measured length using a depth gauge and then replaced with another that was 1 and 2 mm longer, respectively. The actual protruded length of each screw was determined using computed tomography (CT) images. The accuracy of US and DTV measurements was determined using the intraclass correlation coefficient (ICC), as both measurements were compared with CT measurements. The ICC of US and DTV was 0.96 and 0.75, respectively, for all screws. After excluding the data for proximal-row screws, the ICC of US remained unchanged at 0.96, and that of DTV improved to 0.86. The ICC of US was significantly higher than that of DTV (p < 0.01). US had a 100% detection rate for screw protrusion of more than 1.0 mm. US examination showed excellent consistency with CT measurements and its accuracy was not affected by screw location. US might thus be a practical tool for detecting dorsal cortex screw penetration during volar distal radius plating.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.25341DOI Listing

Publication Analysis

Top Keywords

dorsal tangential
8
tangential view
8
screw penetration
8
penetration volar
8
distal radius
8
dtv
5
comparison ultrasound
4
dorsal
4
ultrasound dorsal
4
view dorsal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!