Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Procalcitonin (PCT) is one of the best validated biomarkers in the management of sepsis. However, its prognostic utility remains poorly studied. The present study sought to assess the prognostic utility of serial PCT assessments in patients with sepsis, and to compare the prognostic predictive capability of serial measurements of PCT with conventional markers of inflammation and validated intensive care unit (ICU) severity scoring systems. We recruited consecutive patients admitted to the medical units of a tertiary care center with suspected or proven bacterial infection and sepsis. Measurement of serum PCT levels, inflammatory markers, and ICU severity scores were performed at admission and repeated every 48 hours subsequently for the duration of hospital stay. 99 patients with bacterial infection and sepsis were recruited and followed until death or discharge. Median serum PCT level was similar between survivors and non-survivors on day 1, but was significantly lower at days 3, 5 and 7 in the survivors. The analysis found Acute Physiology and Chronic Health Evaluation (APACHE IV) score on all days (1, 3, 5, and 7), PCT on days 5 and 7, and Sequential Organ Failure Assessment score at 24 hours to have good predictive accuracy for adverse patient outcome. PCT clearance on days 3 and 5 of admission was measured and demonstrated predictive accuracy comparable to day-matched APACHE IV scores. While serial levels of serum PCT in patients with sepsis are accurate in the prediction of adverse patient outcome, they do not offer any additional clinical benefit over existing severity of illness scores and may be cost prohibitive in resource-limited settings. While serial levels of serum PCT in patients with sepsis are accurate in the prediction of adverse patient outcome, they do not offer any additional clinical benefit over existing severity of illness scores and may be cost prohibitive in resource-limited settings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/jim-2021-002276 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!