Contact allergy to cardiac implantable electronic devices is a rare problem in patients. Clinical evaluation and patch tests have an important place in its diagnosis. Also in this case, the diagnosis is supported by ultrasonography. It has been reported in the literature that allergic dermatitis developed after permanent pacemaker implantation in the first few days until the current year. In our case report, we showed that the allergic reaction in the patient was too late. In this article, we present a 94-year-old male patient with a permanent pacemaker who came to us with the complaint of redness and itching in the left chest area and was diagnosed with contact allergy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5543/tkda.2022.21147 | DOI Listing |
Heliyon
January 2025
Faculty of Medicine and Medical Sciences, University of Balamand, Kalhat, Lebanon.
Background: Transvenous pacemakers (TVP) and leadless pacemakers (LP) are two reliable permanent modalities for the treatment of heart rhythm disorders. Several observational studies explored the safety and efficacy of the two devices. The aim of this meta-analysis study is to present a comparative analysis of the safety of leadless versus transvenous pacemakers.
View Article and Find Full Text PDFBackground: Surgical aortic valve replacement (SAVR) is the commonly used approach for aortic valve replacement (AVR) in patients with aortic stenosis at low or intermediate surgical risk. However, transcatheter aortic valve replacement (TAVR) has emerged as an alternative to SAVR for AVR. This meta-analysis aims to assess the comparative efficacy and safety of TAVR versus SAVR in low-to-intermediate surgical risk patients by analyzing temporal trends in the outcomes of TAVR and SAVR at various follow-up intervals, providing a more detailed understanding.
View Article and Find Full Text PDFBMJ Case Rep
November 2024
Cardiology, University Hospitals of Leicester NHS Trust, Leicester, UK.
We describe a rare case of serositis complicating permanent pacemaker implantation presenting 4 weeks postinsertion. A high index of suspicion for this potentially fatal complication is warranted to enable prompt diagnosis and treatment. Serositis should be considered in the differential diagnosis of a patient presenting with chest pain, fever or fatigue following recent permanent pacemaker implantation, particularly if there are elevated inflammatory markers.
View Article and Find Full Text PDFHeart Rhythm O2
December 2024
Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer Sheva, Israel.
Background: Transcatheter aortic valve replacement (TAVR) has revolutionized the management of aortic stenosis and has become the standard of care across a broad spectrum of patients with aortic stenosis. However, it is still associated with high incidence of conduction abnormalities, particularly new left bundle branch block (LBBB). Management of these patients remains a challenge.
View Article and Find Full Text PDFCirc Rep
January 2025
Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University Sapporo Japan.
Background: Because it is unclear whether implantable cardioverter-defibrillators (ICDs) are equally effective in patients of all ages, we investigated the association of age with long-term clinical outcomes of patients who underwent ICD implantation.
Methods And Results: A total of 416 consecutive patients (mean age: 69 years) from 4 tertiary hospitals who underwent ICD implantation or were upgraded from an existing permanent pacemaker between January 2011 and November 2022 were enrolled and divided into 3 groups based on age: <65 years (n=158), 65-74 years (n=138), and ≥75 years (n=120). We compared the incidence of all-cause death and adverse cardiovascular events, including cardiac death, appropriate ICD therapy, and heart failure hospitalization.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!