Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Kinetics measurements of antigen-antibody binding interactions are critical to understanding the functional efficiency of SARS-CoV-2 antibodies. Previously reported chaotrope-based avidity assays that rely on artificial disruption of binding do not reflect the natural binding kinetics. This study developed a chaotrope- and label-free biolayer interferometry (BLI) assay for the real-time monitoring of receptor binding domain (RBD) binding kinetics with SARS-CoV-2 spike protein in convalescent COVID-19 patients. An improved conjugation biosensor probe coated with streptavidin-polysaccharide (SA-PS) led to a six-fold increase of signal intensities and two-fold reduction of non-specific binding (NSB) compared to streptavidin only probe. Furthermore, by utilizing a separate reference probe and biotin-human serum albumin (B-HSA) blocking process to subtracted NSB signal in serum, this BLI biosensor can measure a wide range of the dissociation rate constant (k), which can be measured without knowledge of the specific antibody concentrations. The clinical utility of this improved BLI kinetics assay was demonstrated by analyzing the k values in sera of 24 pediatric (≤18 years old) and 63 adult (>18 years old) COVID-19 convalescent patients. Lower k values for SARS-CoV-2 serum antibodies binding to RBD were measured in samples from children. This rapid, easy to operate and chaotrope-free BLI assay is suitable for clinical use and can be readily adapted to characterize SARS-CoV-2 antibodies developed by COVID-19 patients and vaccines.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8993703 | PMC |
http://dx.doi.org/10.1016/j.bios.2022.114237 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!