Objective: The main objective of this study was to evaluate intra- and inter-rater reliability in the analysis of digital images of donor areas for skin in burn patients using the CaPAS plugin in the ImageJ®.

Methods: Donor sites were reviewed by two independent reviewers in duplicate. The capture of images was standardized on the same device and distance (with a millimeter ruler), without a flash. The evaluators were trained to capture the images and use the plugin.

Results: We selected 70 images from donor areas, from men and women between 18 and 60 years old. In the analysis of intra-examiner reliability, eight of the nine variables exhibited excellent reliability (0.985-0.998) and one (entropy) exhibited good reliability (0.525). The same was true for the inter-examiner analysis: excellent reliability for eight variables (0.824-0.993) and good reliability for entropy (0.501).

Conclusions: The CaPAS plugin has proven to be a reliable tool for use in research in skin donor areas in burns, as demonstrated by its excellent intra- and inter-examiner reliability values. This is a pioneering study in the quantitative assessment of skin donor areas in burn patients using the CaPAS plugin.

Download full-text PDF

Source
http://dx.doi.org/10.1590/1806-9282.20210982DOI Listing

Publication Analysis

Top Keywords

donor areas
20
skin donor
12
capas plugin
12
intra- inter-examiner
8
reliability
8
inter-examiner reliability
8
digital images
8
areas burns
8
images donor
8
burn patients
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!