A recent trend in microfluidic microbial fuel cells (MFCs) is to exclude a separation membrane, instead, relying on the physics of laminar flow to maintain isolation between anode and cathode compartments. To avoid solution crossover, the electrodes may be separated by distances of several millimeters, but this negatively affects the internal resistance and undermines a prime advantage of microscale MFCs. Therefore, we propose a facile method for synthesis of a micromembrane that supports sub-millimeter electrode spacing. Membrane synthesis reduces device fabrication complexity, and the proposed design avoids electrode contamination during its synthesis. Comparing results to a state-of-the-art membraneless MFC with 6 mm inter-electrode distances, the sub-millimeter membrane MFC under comparable flow conditions had an internal resistance that was 60% lower, power and current densities that were respectively 45% and 290% higher, and acetate conversion efficiencies that were 8 times higher. The enhanced flow stability provided stable operation under imbalanced flow conditions and delivered continuous increases to power density of up to 30% for flow rate increases of 100 times over baseline levels. As a result, maximum outputs obtained were 660 mW m and 3.5 A m. These are the highest reported for microfluidic MFCs using pure culture bacteria, which advances the goal of competing with mainstream MFC formats.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d2lc00098aDOI Listing

Publication Analysis

Top Keywords

microfluidic microbial
8
microbial fuel
8
fuel cells
8
internal resistance
8
flow conditions
8
flow
5
mainstreaming microfluidic
4
cells biocompatible
4
membrane
4
biocompatible membrane
4

Similar Publications

SUMMARYThe development of multicellularity represents a key evolutionary transition that is crucial for the emergence of complex life forms. Although multicellularity has traditionally been studied in eukaryotes, it originates in prokaryotes. Coordinated aggregation of individual cells within the confines of a colony results in emerging, higher-level functions that benefit the population as a whole.

View Article and Find Full Text PDF

Microbial contamination is an important factor threatening the safety of Chinese medicine preparations, and microfluidic detection methods have demonstrated excellent advantages in the application of rapid bacterial detection. In our study, a novel optical biosensor was developed for the rapid and sensitive detection of in traditional Chinese medicine on a microfluidic chip. Immune gold@platinum nanocatalysts (Au@PtNCs) were utilized for specific bacterial labeling, while magnetic nano-beads (MNBs) with a novel high-gradient magnetic field were employed for the specific capture of bacteria.

View Article and Find Full Text PDF

High-throughput screening strategies for plastic-depolymerizing enzymes.

Trends Biotechnol

January 2025

Key Laboratory of Engineering Biology for Low-Carbon Manufacturing, Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences, Tianjin 300308, China; National Technology Innovation Center of Synthetic Biology, Tianjin 300308, China. Electronic address:

A multitude of plastic-depolymerizing microorganisms and enzymes have been discovered in the plastisphere. Identifying and engineering such microbial strains and enzymes necessitate robust and high-throughput screening strategies for developing effective microbial solutions to counter the plastic accumulation problem and decouple the reliance on fossil resources. This review covers new methods and approaches for the effective high-throughput screening of depolymerizing enzymes for various plastics, such as polyethylene terephthalate (PET), polyurethane (PU), and polylactic acid (PLA).

View Article and Find Full Text PDF

Advances in tissue engineering and microfluidic technologies have enabled the development of sophisticated models known as organ-on-a-chip (OoC) or microphysiological systems. These systems enable to potential to simulate the dynamic interactions between host tissues and their microenvironment including microbes, biomaterials, mechanical forces, pharmaceutical, and consumer-care products. These fluidic technologies are increasingly being utilized to investigate host-microbe and host-material interactions in oral health and disease.

View Article and Find Full Text PDF

A single microfluidic device for multi-omics analysis sample preparation.

Lab Chip

January 2025

Spectrométrie de Masse Biologique et Protéomique SMBP, ESPCI Paris, LPC CNRS UMR 8249, PSL University, 10 Rue Vauquelin, F-75005 Paris, France.

Combining different "omics" approaches, such as genomics and proteomics, is necessary to generate a detailed and complete insight into microbiome comprehension. Proper sample collection and processing and accurate analytical methods are crucial in generating reliable data. We previously developed the ChipFilter device for proteomic analysis of microbial samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!