Methylammonium lead bromide is a very perspective hybrid semiconductor material, suitable for high-sensitive, filter-free photodetection of electromagnetic radiation. Herein, we studied the effect of electrode spacing on the output performance and stability of planar-type photodetectors based on high-quality MAPbBr single crystals. Such crystals, as large as 4.5×4.5×1.2 mm were synthesized via the inverse temperature crystallization method and were further used for the fabrication of planar Au/MAPbBr/Au photodetectors with variable electrode spacing (in the range between 125 and 25 μm). We report that the electrode spacing has a profound impact on photocurrent densities and key detector parameters (responsivity , external quantum efficiency , and specific detectivity *). In the studied fivefold electrode spacing, the photocurrent density increased over 4 times, with decreasing active area of the devices. This effect is attributed to intrinsic photocurrent amplification. Based on the transient photocurrent measurements and calculated key parameters, we determined the device sample with the best output performance. The champion sample with an electrode spacing of 50 μm exhibited great detection ability, especially for a low light intensity of 200 nWcm, for which we calculated the of 19.55 A W, of 4253%, and * of 3.42 × 10 Jones (cm Hz W). Moreover, the functional stability of this device showed a minimal reduction of photodetection ability after 2000 cycles, which makes it very promising for the next generation of optoelectronic devices.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.1c24362DOI Listing

Publication Analysis

Top Keywords

electrode spacing
24
output performance
12
planar-type photodetectors
8
photodetectors based
8
methylammonium lead
8
lead bromide
8
single crystals
8
electrode
6
spacing
5
spacing determinant
4

Similar Publications

Pre-intercalated Sodium Ions Enhance Sodium Storage of MoS Anode by Mitigating Structural Dissociation.

Nano Lett

January 2025

School of Chemical Engineering and Technology, State Key Laboratory of Chemical Engineering, International Joint Laboratory of Low-carbon Chemical Engineering of Ministry of Education, Tianjin University, Tianjin 300072, P. R. China.

Molybdenum disulfide (MoS) is a promising anode for sodium-ion batteries (SIBs) due to its high theoretical capacity and layered structure. However, a poor reversible conversion reaction and a low initial Coulombic efficiency (ICE) limit its practical application. This study systematically investigated the potential of pre-intercalated sodium ions molybdenum disulfide (Na-MoS) as an anode material for SIBs.

View Article and Find Full Text PDF

This paper highlights the optimisation of a key design parameter essential to the development of PMUTs, which are part of the transmitting components of microsensors. These microsensors are designed for use in the Structural Health Monitoring of reinforced concrete structures. Enhancing the effectiveness of the transmitting component allows for greater spacing between microsensors, which in turn reduces the number of devices needed to implement a full structural health monitoring system.

View Article and Find Full Text PDF

Aqueous zinc-based batteries (AZBs) are gaining widespread attention owing to their intrinsic safety, relatively low electrode potential, and high theoretical capacity. Transition metal dichalcogenides (TMDs) have convenient 2D ion diffusion channels, so they have been identified as promising host materials for AZBs, but face several key challenges such as the narrow interlayer spacing and the lack of in-deep understanding energy storage mechanisms. This review presents a comprehensive summary and discussion of the intrinsic structure, charge storage mechanisms, and key fabrication strategies of TMD-based cathodes for AZBs.

View Article and Find Full Text PDF

Whole-Heart Histological and CMR Validation of Electroanatomic Mapping by Multielectrode Catheters in an Ovine Model.

JACC Clin Electrophysiol

January 2025

Department of Cardiology, Westmead Hospital, Sydney, New South Wales, Australia; Westmead Applied Research Centre, University of Sydney, Sydney, New South Wales, Australia. Electronic address:

Background: Accurate electroanatomic mapping is critical for identifying scar and the long-term success of ventricular tachycardia ablation.

Objectives: This study sought to determine the accuracy of multielectrode mapping (MEM) catheters to identify scar on cardiac magnetic resonance (CMR) and histopathology.

Methods: In an ovine model of myocardial infarction, we examined the effect of electrode size, spacing, and mapping rhythm on scar identification compared to CMR and histopathology using 5 multielectrode mapping catheters.

View Article and Find Full Text PDF

The integrated frequency comb generator based on Kerr parametric oscillation has led to chip-scale, gigahertz-spaced combs with new applications spanning hyperscale telecommunications, low-noise microwave synthesis, light detection and ranging, and astrophysical spectrometer calibration. Recent progress in lithium niobate (LiNbO) photonic integrated circuits (PICs) has resulted in chip-scale, electro-optic (EO) frequency combs, offering precise comb-line positioning and simple operation without relying on the formation of dissipative Kerr solitons. However, current integrated EO combs face limited spectral coverage due to the large microwave power required to drive the non-resonant capacitive electrodes and the strong intrinsic birefringence of LiNbO.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!