Background: Laparoscopic hepatectomy has recently become popular because it results in less bleeding than open hepatectomy. However, CO embolism occurs more frequently. Most CO embolisms during laparoscopic surgery are self-resolving and non-symptomatic; however, severe CO embolism may cause hypotension, cyanosis, arrhythmia, and cardiovascular collapse. In particular, paradoxical CO embolisms are highly likely to cause neurological deficits. We report a case of paradoxical CO embolism found on transesophageal echocardiography (TEE) during laparoscopic hepatectomy, although the patient had no intracardiac shunt.

Case Summary: A 71-year-old man was admitted for laparoscopic left hemihepatectomy. During left hepatic vein ligation, the inferior vena cava was accidentally torn. We observed a sudden drop in oxygen saturation to 85%, decrease in systolic blood pressure (SBP) below 90 mmHg, and reduction in end-tidal CO to 24 mmHg. A "mill-wheel" murmur was auscultated over the precordium. The fraction of inspired oxygen was increased to 100% with 5 cmHO of positive end-expiratory pressure (PEEP) and hyperventilation was maintained. Norepinephrine infusion was increased to maintain SBP above 90 mmHg. A TEE probe was inserted, revealing gas bubbles in the right side of the heart, left atrium, left ventricle, and ascending aorta. The surgeon reduced the pneumoperitoneum pressure from 17 to 14 mmHg and repaired the damaged vessel laparoscopically. Thereafter, the patient's hemodynamic status stabilized. The patient was transferred to the intensive care unit, recovering well without complications.

Conclusion: TEE monitoring is important to quickly determine the presence and extent of embolism in patients undergoing laparoscopic hepatectomy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8968813PMC
http://dx.doi.org/10.12998/wjcc.v10.i9.2908DOI Listing

Publication Analysis

Top Keywords

laparoscopic hepatectomy
16
sbp mmhg
8
laparoscopic
6
embolism
5
hepatectomy
5
paradoxical carbon
4
carbon dioxide
4
dioxide embolism
4
embolism laparoscopic
4
hepatectomy intracardiac
4

Similar Publications

The dorsal approach to the middle hepatic vein from the hilar plate in laparoscopic hemihepatectomy (with video).

World J Surg

December 2024

Center for Liver and Pancreatobiliary Cancer, National Cancer Center, Goyang-si, Gyeonggi-do, South Korea.

Background: Although laparoscopic hemihepatectomy has gained prominence, one of the critical challenges in this procedure is the approach to the middle hepatic vein (MHV). The MHV, which runs in the midplane of the liver, is situated above the hilar plate and serves as an anatomical landmark in hemihepatectomy. We have introduced dorsal approach to the MHV from the hilar plate in laparoscopic hemihepatectomy under the laparoscopic caudo-dorsal view.

View Article and Find Full Text PDF

The rapid advances in laparoscopic surgery have meant that formerly complex techniques are now commonly performed via this method. These practices are now becoming increasingly popular in the discipline of hepatopancreaticobiliary (HPB) surgery. One such example is liver resection, which is the focus of our review.

View Article and Find Full Text PDF

Background: Colorectal cancer (CRC) frequently metastasizes to the liver, significantly worsening patient outcomes. While hepatectomy offers the best curative option for colorectal liver metastases (CRLM), margin recurrence remains a major challenge post-surgery. Intraoperative ultrasound (IOUS) aids tumor identification and margin determination, but its limitations in laparoscopic surgery necessitate additional methods.

View Article and Find Full Text PDF

Background: Laparoscopic parenchyma-sparing hepatectomy (PSH) is an effective treatment for colorectal liver metastases (CRLMs), but ensuring the safety and radicality of the procedure, particularly for deep-seated tumors, remains challenging. Surgical navigation technologies such as augmented reality navigation (ARN) and indocyanine green fluorescence imaging (ICG-FI) are increasingly utilized to guide surgery, yet their efficacy for CRLMs is unclear. This study aims to evaluate the short- and long-term outcomes of ARN combined with ICG-FI-guided (ARN-FI) laparoscopic PSH for CRLMs.

View Article and Find Full Text PDF

Objective: To compare nationwide outcomes of robotic liver resection (RLR) with laparoscopic liver resection (LLR).

Background: Minimally invasive liver resection is increasingly performed using the robotic approach as this could help overcome inherent technical limitations of laparoscopy. It is unknown if this translates to improved patient outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!