A new principle of pulse detection based on terahertz wave plethysmography.

Sci Rep

Center for Wireless Information Systems and Computational Architectures (WISCA) at the School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ, 85281, USA.

Published: April 2022

This study presents findings in the terahertz (THz) frequency spectrum for non-contact cardiac sensing applications. Cardiac pulse information is simultaneously extracted using THz waves based on the established principles in electronics and optics. The first fundamental principle is micro-Doppler motion effect. This motion based method, primarily using coherent phase information from the radar receiver, has been widely exploited in microwave frequency bands and has recently found popularity in millimeter waves (mmWave) for breathe rate and heart rate detection. The second fundamental principle is reflectance based optical measurement using infrared or visible light. The variation in the light reflection is proportional to the volumetric change of the heart, often referred as photoplethysmography (PPG). Herein, we introduce the concept of terahertz-wave-plethysmography (TPG), which detects blood volume changes in the upper dermis tissue layer by measuring the reflectance of THz waves, similar to the existing remote PPG (rPPG) principle. The TPG principle is justified by scientific deduction, electromagnetic wave simulations and carefully designed experimental demonstrations. Additionally, pulse measurements from various peripheral body parts of interest (BOI), palm, inner elbow, temple, fingertip and forehead, are demonstrated using a wideband THz sensing system developed by the Terahertz Electronics Lab at Arizona State University, Tempe. Among the BOIs under test, it is found that the measurements from forehead BOI gives the best accuracy with mean heart rate (HR) estimation error 1.51 beats per minute (BPM) and standard deviation 1.08 BPM. The results validate the feasibility of TPG for direct pulse monitoring. A comparative study on pulse sensitivity is conducted between TPG and rPPG. The results indicate that the TPG contains more pulsatile information from the forehead BOI than that in the rPPG signals in regular office lighting condition and thus generate better heart rate estimation statistic in the form of empirical cumulative distribution function of HR estimation error. Last but not least, TPG penetrability test for covered skin is demonstrated using two types of garment materials commonly used in daily life.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9012849PMC
http://dx.doi.org/10.1038/s41598-022-09801-wDOI Listing

Publication Analysis

Top Keywords

heart rate
12
thz waves
8
fundamental principle
8
forehead boi
8
rate estimation
8
estimation error
8
tpg
6
principle
5
principle pulse
4
pulse detection
4

Similar Publications

E-point septal separation (EPSS) and tricuspid annular plane systolic excursion (TAPSE) are M-mode measures of left and right ventricular systolic function, with limited pediatric point-of-care ultrasound (POCUS) research. We conducted a cross-sectional study in a pediatric emergency department, enrolling 12-17-year-olds without cardiopulmonary complaints. Exclusion criteria included abnormal vital signs, fever, altered mental status, or psychiatric illness.

View Article and Find Full Text PDF

Background: While the effects of sleep deprivation on cognitive function are well-documented, its impact on high-intensity endurance performance and underlying neural mechanisms remains underexplored, especially in the context of search and rescue operations where both physical and mental performance are essential. This study examines the neurophysiological basis of sleep deprivation on high-intensity endurance using electroencephalography (EEG). In this crossover study, twenty firefighters were subjected to both sleep deprivation (SD) and normal sleep conditions, with each participant performing endurance treadmill exercise the following morning after each condition.

View Article and Find Full Text PDF

The Effect of Music Combined With Preoperative Education on Perioperative Anxiety in Patients Undergoing Open Cardiac Surgery: A Randomized Controlled Trial.

J Perianesth Nurs

January 2025

Department of Anesthesiology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, China. Electronic address:

Purpose: The aim of this study is to observe the effect of music combined with preoperative education on perioperative anxiety in patients undergoing open cardiac surgery.

Design: This was a randomized controlled study.

Methods: A group of 322 patients undergoing elective open cardiac surgery were randomly allocated to receive either music combined with preoperative education (the experimental group) or routine preoperative preparation (the control group).

View Article and Find Full Text PDF

Background: Chronic limb-threatening ischemia (CLTI) in patients with chronic kidney disease (CKD) has a high risk of poor outcomes. We aimed to compare the outcomes of lower extremity revascularization in patients with CLTI stratified by CKD severity in patients enrolled in the prospective, randomized Best Endovascular vs Best Surgical Therapy in Patients with CLTI (BEST-CLI) trial.

Methods: The BEST-CLI trial dataset was queried to categorize patients into three groups according to CKD stage.

View Article and Find Full Text PDF

Restitution Threshold Index: Looking Beyond the Mean Heart Rate.

JACC Clin Electrophysiol

January 2025

Division of Cardiac Electrophysiology, Virginia Commonwealth University, Richmond, Virginia, USA; Division of Cardiac Electrophysiology, Central Virginia Veterans Affairs Health System, Richmond, Virginia, USA. Electronic address:

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!