Gattinoni's equation, [Formula: see text], now commonly used to calculate the mechanical power (MP) of ventilation. However, it calculates only inspiratory MP. In addition, the inclusion of PEEP in Gattinoni's equation raises debate because PEEP does not produce net displacement or contribute to MP. Measuring the area within the pressure-volume loop accurately reflects the MP received in a whole ventilation cycle and the MP thus obtained is not influenced by PEEP. The MP of 25 invasively ventilated patients were calculated by Gattinoni's equation and measured by integration of the areas within the pressure-volume loops of the ventilation cycles. The MP obtained from both methods were compared. The effects of PEEPs on MP were also evaluated. We found that the MP obtained from both methods were correlated by R = 0.75 and 0.66 at PEEP 5 and 10 cmHO, respectively. The biases of the two methods were 3.13 (2.03 to 4.23) J/min (P < 0.0001) and - 1.23 (- 2.22 to - 0.24) J/min (P = 0.02) at PEEP 5 and 10 cmHO, respectively. These P values suggested that both methods were significantly incongruent. When the tidal volume used was 6 ml/Kg, the MP by Gattinoni's equation at PEEP 5 and 10 cmHO were significantly different (4.51 vs 7.21 J/min, P < 0.001), but the MP by PV loop area was not influenced by PEEPs (6.46 vs 6.47 J/min, P = 0.331). Similar results were observed across all tidal volumes. We conclude that the Gattinoni's equation is not accurate in calculating the MP of a whole ventilatory cycle and is significantly influenced by PEEP, which theoretically does not contribute to MP.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9637605 | PMC |
http://dx.doi.org/10.1007/s10877-022-00823-3 | DOI Listing |
Am J Physiol Lung Cell Mol Physiol
November 2024
Department of Bioengineering, University of Colorado Denver | Anschutz Medical Campus, Aurora, Colorado, USA.
Mechanical ventilation is a necessary lifesaving intervention for patients with Acute Respiratory Distress Syndrome (ARDS) but it can cause ventilator induced lung injury (VILI), which contributes to the high ARDS mortality rate (≈40%). Bedside determination of optimally lung-protective ventilation settings is challenging because the evolution of VILI is not immediately reflected in clinically available, patient-level, data. The goal of this work was therefore to test ventilation waveform-derived parameters that represent the degree of ongoing VILI and can serve as targets for ventilator adjustments.
View Article and Find Full Text PDFJ Clin Monit Comput
December 2022
Department of Medical Research, Taipei Veterans General Hospital, No. 201, Sec. 2, Shihpai Rd, Beitou District, Taipei, 112, Taiwan.
Gattinoni's equation, [Formula: see text], now commonly used to calculate the mechanical power (MP) of ventilation. However, it calculates only inspiratory MP. In addition, the inclusion of PEEP in Gattinoni's equation raises debate because PEEP does not produce net displacement or contribute to MP.
View Article and Find Full Text PDFJ Crit Care
April 2020
Department of Anesthesiology and Reanimation, School of Medicine, Koç University, Istanbul, Turkey.
Purpose: To develop an equation to calculate the bedside dynamic mechanical power (MP) for modern ventilators using the Work of Breathing ventilator (WOBv) parameter.
Materials And Methods: We developed an equation based on mechanical power values, which is equal to WOBv x minute volume. To measure mechanical power with this equation forty adult patients, hospitalized with the diagnosis of Acute Respiratory Distress Syndrome and underwent invasive mechanical ventilation, were used.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!