Knee extensor force production and discomfort during neuromuscular electrical stimulation of quadriceps with and without gluteal muscle co-stimulation.

Eur J Appl Physiol

Integrative Orthopedic Laboratory, Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.

Published: June 2022

Purpose: To investigate whether Neuromuscular Electrical Stimulation (NMES) simultaneously applied on the quadriceps (Q) and gluteal (G) muscles, as compared to single Q-stimulation alters the knee extensor force production and discomfort.

Methods: A total of 11 healthy participants (6 females), with normal weight and age between 19 and 54 years were included. The unilateral, isometric maximal voluntary contraction (MVC) was assessed for each participant in an isokinetic dynamometer (Biodex, system 3). NMES was, in a randomized order, applied only on the Q-muscle and on the Q- and G-muscles (QG) simultaneously. NMES-intensity was increased stepwise until the maximal tolerable level was reached regarding discomfort, graded according to the visual analogue scale (VAS). VAS and the % of MVC produced by NMES, were registered for each level, expressed as median (inter-quartile range).

Results: The maximum tolerated NMES-intensity applied on Q compared to QG resulted in equally high discomfort, 8.0 (6.0-9.0) vs 8.0 (6.3-9.0), and in equivalent knee extensor force production, 36.7 (29.9-47.5) and 36.2 (28.9-49.3), respectively, in % of MVC. At 20% of MVC, NMES applied on Q compared to QG resulted in equal acceptable discomfort, 3.0 (2.0-4.5) vs 3.0 (3-5.5), and comparable intensity levels, 41.5 (38.0-45.8) vs 43.5 (37.0-48.8), respectively.

Conclusions: Simultaneous QG-NMES, as compared to single Q-NMES, does not seem to affect the knee extensor force production or discomfort. Q-NMES, without voluntary muscle contraction, can with an acceptable level of discomfort result in at least 20% of MVC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9132842PMC
http://dx.doi.org/10.1007/s00421-022-04949-9DOI Listing

Publication Analysis

Top Keywords

knee extensor
16
extensor force
16
force production
16
production discomfort
8
neuromuscular electrical
8
electrical stimulation
8
quadriceps gluteal
8
compared single
8
applied compared
8
20% mvc
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!