Introduction: Firefighters are exposed to volatile organic compounds (VOCs) during structural fire responses and training fires, several of which (e.g., benzene, acrolein, styrene) are known or probable carcinogens. Exposure studies have found that firefighters can absorb chemicals like benzene even when self-contained breathing apparatus (SCBA) are worn, suggesting that dermal absorption contributes to potentially harmful exposures. However, few studies have characterized VOC metabolites in urine from firefighters.

Objectives: We quantified VOC metabolites in firefighters' urine following live firefighting activity across two field studies.

Methods: In two separate controlled field studies, spot urine was collected before and 3 h after firefighters and firefighter students responded to simulated residential and training fires. Urine was also collected from instructors from the training fire study before the first and 3 h after the last training scenario for each day (instructors led three training scenarios per day). Samples were analyzed for metabolites of VOCs to which firefighters may be exposed.

Results: In the residential fire study, urinary metabolites of xylenes (2MHA), toluene (BzMA), and styrene (MADA) increased significantly (at 0.05 level) from pre- to post-fire. In the training fire study, MADA concentrations increased significantly from pre- to post-fire for both firefighter students and instructors. Urinary concentrations of benzene metabolites (MUCA and PhMA) increased significantly from pre- to post-fire for instructors, while metabolites of xylenes (3MHA+4MHA) and acrolein (3HPMA) increased significantly for firefighter students. The two highest MUCA concentrations measured post-shift from instructors exceeded the BEI of 500 μg/g creatinine.

Conclusions: Some of the metabolites that were significantly elevated post-fire are known or probable human carcinogens (benzene, styrene, acrolein); thus, exposure to these compounds should be eliminated or reduced as much as possible through the hierarchy of controls. Given stringent use of SCBA, it appears that dermal exposure contributes in part to the levels measured here.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9969558PMC
http://dx.doi.org/10.1016/j.ijheh.2022.113969DOI Listing

Publication Analysis

Top Keywords

voc metabolites
12
training fire
12
firefighter students
12
fire study
12
pre- post-fire
12
urinary concentrations
8
metabolites
8
fire responses
8
training fires
8
urine collected
8

Similar Publications

Hearing loss (HL) is an otolaryngology disease susceptible to environmental pollutants. Volatile organic compounds (VOCs), as a class of chemical pollutants with evaporation propensity, pose a great threat to human health. However, the association between VOCs and HL remains unclear.

View Article and Find Full Text PDF

Introduction: Breath Volatile organic compounds (VOCs) are promising biomarkers for clinical purposes due to their unique properties. Translation of VOC biomarkers into the clinic depends on identification and validation: a challenge requiring collaboration, well-established protocols, and cross-comparison of data. Previously, we developed a breath collection and analysis method, resulting in 148 breath-borne VOCs identified.

View Article and Find Full Text PDF

High-throughput UPLC-ESI/MSMS method for simultaneous measurement of the urinary metabolites of volatile organic compounds and tobacco alkaloids.

J Chromatogr B Analyt Technol Biomed Life Sci

January 2025

Christina Lee Brown Envirome Institute, University of Louisville, Louisville, KY 40202, United States; Superfund Research Center, University of Louisville, Louisville, KY 40202, United States; Division of Environmental Medicine, Department of Medicine, University of Louisville, Louisville, KY 40202, United States. Electronic address:

Human exposure to volatile organic compounds (VOCs) poses significant health risks, contributing to cardiovascular disease, pulmonary disease, and cancer. Measurement of VOC metabolites (VOCm) in urine by liquid chromatography-mass spectrometry (LC-MS) is a preferred method for VOCm analysis; however, existing methods encounter challenges related to sensitivity, throughput, and analyte coverage. In addition to VOCm, the measurement of tobacco alkaloids (TAm) is critical to account for tobacco use in population-based studies.

View Article and Find Full Text PDF

The clinical diagnosis of dermatophytosis and identification of dermatophytes face challenges due to reliance on culture-based methods. Rapid, cost-effective detection techniques for volatile organic compounds (VOCs) have been developed for other microorganisms, but their application to dermatophytes is limited. This study explores using VOCs as diagnostic markers for dermatophytes.

View Article and Find Full Text PDF

Early detection of bacterial pneumonia by characteristic induced odor signatures.

BMC Infect Dis

December 2024

Department of Infectious Diseases and Hospital Epidemiology, University Hospital Zurich, University of Zürich, Zurich, 8097, Switzerland.

Introduction: The ability to detect pathogenic bacteria before the onsets of severe respiratory symptoms and to differentiate bacterial infection allows to improve patient-tailored treatment leading to a significant reduction in illness severity, comorbidity as well as antibiotic resistance. As such, this study refines the application of the non-invasive Secondary Electrospray Ionization-High Resolution Mass Spectrometry (SESI-HRMS) methodology for real-time and early detection of human respiratory bacterial pathogens in the respiratory tract of a mouse infection model.

Methods: A real-time analysis of changes in volatile metabolites excreted by mice undergoing a lung infection by Staphylococcus aureus or Streptococcus pneumoniae were evaluated using a SESI-HRMS instrument.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!