A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fall Risk Assessment for the Elderly Based on Weak Foot Features of Wearable Plantar Pressure. | LitMetric

The high fall rate of the elderly brings enormous challenges to families and the medical system; therefore, early risk assessment and intervention are quite necessary. Compared to other sensor-based technologies, in-shoe plantar pressure sensors, effectiveness and low obtrusiveness are widely used for long-term fall risk assessments because of their portability. While frequently-used bipedal center-of-pressure (COP) features are derived from a pressure sensing platform, they are not suitable for the shoe system or pressure insole owing to the lack of relative position information. Therefore, in this study, a definition of "weak foot" was proposed to solve the sensitivity problem of single foot features and facilitate the extraction of temporal consistency related features. Forty-four multi-dimensional weak foot features based on single foot COP were correspondingly extracted; notably, the relationship between the fall risk and temporal inconsistency in the weak foot were discussed in this study, and probability distribution method was used to analyze the symmetry and temporal consistency of gait lines. Though experiments, foot pressure data were collected from 48 subjects with 24 high risk (HR) and 24 low risk (LR) ones obtained by the smart footwear system. The final models with 87.5% accuracy and 100% sensitivity on test data outperformed the base line models using bipedal COP. The results and feature space shown the novel features of wearable plantar pressure could comprehensively evaluate the difference between HR and LR groups. Our fall risk assessment models based on these features had good generalization performance, and showed practicability and reliability in real-life monitoring situations.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNSRE.2022.3167473DOI Listing

Publication Analysis

Top Keywords

fall risk
16
risk assessment
12
weak foot
12
foot features
12
plantar pressure
12
features wearable
8
wearable plantar
8
single foot
8
temporal consistency
8
features
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!