Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: To investigate repair of iris defects by endocapsular implantation of an artificial iris, in relation to visual outcomes, safety profile and patient satisfaction.
Methods: Retrospective, consecutive case series from Greenlane tertiary teaching hospital and Eye Institute, Auckland, New Zealand. Medical records of patients implanted with an endocapsular artificial iris were reviewed and followed for minimum 3 months. Patient characteristics, surgical management, clinical outcomes and subjective responses were recorded.
Results: Nineteen artificial irises were implanted in 18 patients. Etiologies were iris melanotic lesion excision (73.7%), trauma (10.5%), congenital aniridia (10.5%) and Urrets-Zavalia syndrome (5.3%). During postoperative follow-up [14.1 ± 12.4 months (range: 3 to 59 months)], best corrected visual acuity (BCVA) and intraocular pressure (IOP) did not change significantly [BCVA, 0.23 logarithm of the minimum angle of resolution (logMAR) (20/32 Snellen) preoperatively vs. 0.18 logMAR postoperatively (20/25 Snellen) (Z = -0.222, p = 0.824); IOP, 15 mmHg preoperatively vs. 17 mmHg postoperatively (Z = 1.377, p = 0.1447)]. Mild or self-limiting complications included: elevated IOP (42.1%), cystoid macular oedema (15.8%); persisting postoperative uveitis (15.8%) and minor vaulting of the prosthesis (15.7%). Moderate or severe complications included significant vaulting of prosthesis requiring surgical revision (5.3%) and a single eye (5.3%) with trabeculectomy and corneal graft failure. 94.4% of patients were very satisfied with the cosmesis and would be highly likely to have the procedure again.
Conclusions: This study confirms that endocapsular insertion of an artificial iris is typically associated with good functional and cosmetic results and a relatively low risk of significant complications.