AI Article Synopsis

  • A recent study in the Faroe Islands indicated mild iodine deficiency in women over 40, but preliminary results showed a surprisingly high average urinary iodine concentration of 457 µg/L, prompting further investigation.
  • The study involved collecting urine and tap water samples from pregnant women, analyzing iodine levels, and examining the impact of iodine-rich food intake on urinary iodine concentration.
  • Results revealed that urine samples can become contaminated quickly from test strips, leading to unreliable iodine measurements, highlighting the need for strict sample handling protocols in iodine research.

Article Abstract

Objective: A recent report from the Faroe Islands suggested mild iodine deficiency among women aged 40 years and older. New preliminary results showed an average urinary iodine concentration of 457 µg/L. This spurious finding encouraged the present report.

Methods: A subset of 17 consecutive pregnant women from an ongoing study provided an additional morning spot urine sample; one part was tested for a few seconds with a test strip for glucose, protein, and erythrocytes, and the other was left untouched. The women recorded the previous week's intake of iodine-rich foods. Additionally, 12 tap water samples were collected such that three samples were sealed immediately, the remaining were strip tested for 10, 30 and 60 s, respectively. Urine and water samples were analysed using the ceri/arsen method after alkaline ashing.

Results: Median urinary iodine concentration (UIC) in pristine urine samples was 116 µg/L (IQR 79-204 µg/L; range 26-475 µg/L), and positively associated with iodine-rich food intake. UIC increase with test-strip dip varied from 10 to 94 times the non-dip value. In tap water, the pristine samples had an iodine concentration of 2-4 µg/L, which increased to 10,000 µg/L after 60 s.

Conclusion: Urine samples exposed to test strips can be contaminated within a few seconds leading to unreliable iodine results. Therefore, it is crucial that the study protocol clearly states the procedure for urine sample collection and handling, strict adherence to protocol, and that utensils used are dedicated to collecting urine to measure iodine.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00365513.2022.2059699DOI Listing

Publication Analysis

Top Keywords

iodine concentration
12
test strips
8
iodine
8
urinary iodine
8
urine sample
8
tap water
8
water samples
8
urine samples
8
urine
7
samples
6

Similar Publications

Background: Breast cancer (BC) is a common cancer among women worldwide, and although the use of neoadjuvant therapy (NAT) for BC has become more widespread, there is no standardized prediction of the efficacy of NAT for BC. This study aimed to evaluate the value of quantitative parameters of dual-layer detector spectral computed tomography (DLCT) in predicting whether BC patients can achieve pathological complete response (pCR) after NAT.

Methods: Patients who were first diagnosed with BC in Shandong Cancer Hospital and Institute and received only NAT before surgery were selected for participation in this study.

View Article and Find Full Text PDF

Background: Native and periprosthetic joint infections are devastating conditions fraught with patient morbidity and mortality. Aseptic and septic joints are often debrided and irrigated to decrease bacterial loads when preventing or treating infection. However, the effect of clinically used irrigation solutions on the native cellular components of the synovial joint is unknown.

View Article and Find Full Text PDF

Ventriculoperitoneal (VP) shunting is frequently associated with complications of which shunt-related infections are the most common. However, controversies still exist regarding the underlying factors. This study comparing peri-operative skin preparation agents was aimed at determining which factors among previously documented determinants of shunt infection are implicated in our practice setting.

View Article and Find Full Text PDF

Objectives: This study evaluates the performance of a clinical dual-source photon-counting computed tomography (PCCT) system in quantifying iodine within calcified vessels, using 3D- printed phantoms with vascular-like structures lined with calcium.

Methods: Parameters assessed include lumen diameters (4, 6, 8, 10, and 12 mm), phantom sizes (S: 20×20 cm, M: 25×25 cm, L: 30×40 cm, XL: 40×50 cm, representing the 99th percentile of US patient sizes), and iodine concentrations (2, 5, and 10 mg/mL). Scans were performed at radiation dose levels of 5, 10, 15, and 20 mGy to systematically evaluate iodine quantification accuracy and spectral imaging performance.

View Article and Find Full Text PDF

Objectives: The relationship between iodine status and gestational diabetes mellitus (GDM) is inconclusive. This study aimed to explore the trajectories of urinary iodine concentrations (UIC) in pregnant women before GDM diagnosis and to assess the associations between maternal UIC trajectories and the risk of developing GDM.

Methods: A prospective cohort study was conducted in China.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!