Data on preimplantation genetic testing (PGT-M) in patients with genetic susceptibility to cancer are scarce in the literature, while there is, in our experience, a growing familiarity with assisted reproduction techniques (ART) among pathogenic variant heterozygotes. We performed a retrospective multicenter study of PGT-M outcomes among French patients with genetic susceptibility to cancer. Our objectives were to collect data on this complex issue, and to help cancer geneticists counsel their patients of reproductive age. We also wanted to increase awareness regarding PGT-M among cancer genetics professionals. Patients from three university hospital cancer genetics clinics who had requested PGT-M between 2000 and 2019 were included retrospectively. Data were extracted from medical records. Patients were then contacted directly to collect missing and up-to-date information. Out of 41 eligible patients, 28 agreed explicitly to participate when contacted and were therefore included. They carried PV in VHL (n = 9), APC (n = 8), CDH1 (n = 5), STK11 (n = 2), AXIN2, BRCA1, MEN1, and FH (n = 1). Seven patients were denied PGT-M based on multidisciplinary team meetings or subsequently by the ART hospital teams, two changed their minds, and two were yet to start the process. PGT-M was successful in seven patients (25%), with a mean age at PGT-M request of 27. Most had von Hippel-Lindau. PGT-M failed in the remaining ten, with a mean age at PGT-M request of 32. The main reason for failure was non-implantation of the embryo. Of these, four patients were pursuing PGT-M at the time of last contact. PGT-M outcomes in patients with cancer susceptibility syndromes were satisfactory. These patients should be informed about PGT-M more systematically, which would imply greater awareness among cancer genetics professionals regarding ART. Our series was not representative of cancer susceptibility syndromes in general; the predominance of cases with syndromes characterized by early-onset, highly penetrant disease is explained by the restrictive French guidelines.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10689-022-00293-1 | DOI Listing |
Adv Ther
December 2024
Global Medical and Patient Affairs, Servier, Suresnes, France.
Introduction: The aim of the observational SIMPLE study was to assess real-life effectiveness and safety of a single-pill combination (SPC) of perindopril arginine/amlodipine in a broad range of subjects with newly diagnosed mild-to-moderate hypertension treated in Canadian general practice.
Methods: Treatment-naïve participants aged 18-65 years with mild-to-moderate hypertension, whose physicians decided to initiate the perindopril/amlodipine SPC, were recruited from Canadian clinical practice from October 2017 to February 2019. Participants were followed at 3- (M3) and 6-month (M6) visits after treatment initiation.
Adv Ther
December 2024
GSK, US Value Evidence and Outcomes, Collegeville, PA, 19426-0989, USA.
Introduction: Chronic obstructive pulmonary disease (COPD) is associated with exacerbations which can reduce quality of life and increase mortality. Single-inhaler triple therapy (SITT) is recommended for maintenance treatment of COPD among patients experiencing exacerbations despite dual-therapy use. This real-world comparative effectiveness study compared the impact of SITTs, fluticasone furoate/umeclidinium/vilanterol (FF/UMEC/VI), and budesonide/glycopyrrolate/formoterol fumarate (BUD/GLY/FORM), on COPD exacerbations and mortality.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.
Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Electrophysiology and Cardiac Pacing Unit, Pellegrini Hospital, Naples, Italy.
Reel's syndrome (RS) is an unusual cause of pacemaker lead dislodgement. We present the case of a 59-year-old female patient with Down syndrome (DS) implanted with a dual-chamber endovascular pacemaker due to symptomatic sinus node disfunction, reporting several syncopal episodes in last days and showing abnormal electrical parameters at the 2-months follow-up due to RS. The malfunctioning device was removed and an endocardial leadless pacing system was implanted.
View Article and Find Full Text PDFCurr Rheumatol Rep
December 2024
Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, CLS-937, Boston, MA, 02215, USA.
Purpose Of Review: Kidney injury due to lupus nephritis (LN) is a severe and sometimes life-threatening sequela of systemic lupus erythematosus. Autoimmune injury to podocytes has been increasingly demonstrated to be a key driver of LN-related kidney injury because these cells play key roles in glomerular filtration barrier homeostasis. Irreparable podocyte injury impairs these processes and can lead to proteinuria, which is an indicator of poor prognosis in LN.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!