2DE permits detection of thromboemboli transiently entrapped in the right heart chambers while en route to the pulmonary arteries. Review of the 49 cases recorded to date reveals that the supple elongated clot produces a 2DE picture--a mass of changing configuration and striking mobility--that is highly characteristic. Since emboli that become entrapped are large, when managed by medical measures alone they have an attendant mortality rate of 50%, usually soon after 2DE diagnosis, upon completion of pulmonary embolization. Death occurred in 8 of 16 patients treated with anticoagulants, thrombolytic agents, or antiaggregants and in 6 of 13 who received supportive measures only. Of 20 patients referred for surgery (cardiotomy and, in 17, pulmonary embolectomy), only three died, two of them failures of preceding anticoagulant treatment. These data indicate that thromboemboli entrapped in the right heart chambers are best handled as a surgical emergency.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0002-8703(87)90026-3DOI Listing

Publication Analysis

Top Keywords

entrapped heart
8
heart chambers
8
review echocardiographically
4
echocardiographically diagnosed
4
diagnosed heart
4
heart entrapment
4
pulmonary
4
entrapment pulmonary
4
pulmonary emboli-in-transit
4
emboli-in-transit emphasis
4

Similar Publications

Purpose: Subclinical peroneal neuropathy without overt foot drop has been linked to increased fall risk in adults, yet remains under reported due to subtle symptoms and lack of awareness. Patients with carpal tunnel syndrome (CTS) often experience other nerve entrapments, prompting this study to evaluate CTS (a proxy for peroneal nerve entrapment) as a significant predictor of time to first fall.

Methods: Data from the Merative MarketScan Research Databases (2007-2021) were used to identify adult patients using ICD-9/10 codes.

View Article and Find Full Text PDF

Background: Neutrophil Extracellular Traps can contribute to thrombosis via stabilization fibrin network, which is normally conducted by plasma transglutaminase, Factor XIII-A as part of coagulation cascade. The possible presence and activity of FXIII-A in neutrophils or during NETosis is unknown. Here, we investigated potential presence of FXIII-A in neutrophils and participation in NET-fibrinogen interaction.

View Article and Find Full Text PDF
Article Synopsis
  • - Device entrapment during Transcatheter Aortic Valve Implantation (TAVI) is a rare but serious issue, particularly with calcified aorta, as shown in a case involving an 86-year-old female patient where a pigtail catheter got stuck.
  • - After failed attempts to retrieve the catheter, an innovative solution was implemented by inflating a post-dilation balloon to stabilize the valve while safely extracting the trapped catheter without damage or the need for surgery.
  • - The case highlights the need for preventative measures, such as ensuring catheters can move freely and retracting them before fully deploying the valve, to avoid complications in future procedures.
View Article and Find Full Text PDF

Chiari Network: Cause of an Unusual Difficulty during Atrial Septal Defect Device Closure.

Heart Views

October 2024

Department of Cardiology, SKIMS, Srinagar, Jammu and Kashmir, India.

Article Synopsis
  • There was a specific issue encountered while trying to remove an atrial septal defect device during a medical procedure.
  • The problem arose because the delivery cable got stuck in a prominent Chiari network, making it difficult to unscrew and release the device.
  • The authors recommend using careful imaging techniques, like transesophageal guidance, before and during the procedure to help identify and handle this rare challenge.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!