Background: Microscopic examination of Giemsa-stained blood films remains the reference standard for malaria parasite detection and quantification, but is undermined by difficulties in ensuring high-quality manual reading and inter-reader reliability. Automated parasite detection and quantification may address this issue.

Methods: A multi-centre, observational study was conducted during 2018 and 2019 at 11 sites to assess the performance of the EasyScan Go, a microscopy device employing machine-learning-based image analysis. Sensitivity, specificity, accuracy of species detection and parasite density estimation were assessed with expert microscopy as the reference. Intra- and inter-device reliability of the device was also evaluated by comparing results from repeat reads on the same and two different devices. This study has been reported in accordance with the Standards for Reporting Diagnostic accuracy studies (STARD) checklist.

Results: In total, 2250 Giemsa-stained blood films were prepared and read independently by expert microscopists and the EasyScan Go device. The diagnostic sensitivity of EasyScan Go was 91.1% (95% CI 88.9-92.7), and specificity 75.6% (95% CI 73.1-78.0). With good quality slides sensitivity was similar (89.1%, 95%CI 86.2-91.5), but specificity increased to 85.1% (95%CI 82.6-87.4). Sensitivity increased with parasitaemia rising from 57% at < 200 parasite/µL, to ≥ 90% at > 200-200,000 parasite/µL. Species were identified accurately in 93% of Plasmodium falciparum samples (kappa = 0.76, 95% CI 0.69-0.83), and in 92% of Plasmodium vivax samples (kappa = 0.73, 95% CI 0.66-0.80). Parasite density estimates by the EasyScan Go were within ± 25% of the microscopic reference counts in 23% of slides.

Conclusions: The performance of the EasyScan Go in parasite detection and species identification accuracy fulfil WHO-TDR Research Malaria Microscopy competence level 2 criteria. In terms of parasite quantification and false positive rate, it meets the level 4 WHO-TDR Research Malaria Microscopy criteria. All performance parameters were significantly affected by slide quality. Further software improvement is required to improve sensitivity at low parasitaemia and parasite density estimations. Trial registration ClinicalTrials.gov number NCT03512678.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9004086PMC
http://dx.doi.org/10.1186/s12936-022-04146-1DOI Listing

Publication Analysis

Top Keywords

performance easyscan
12
malaria microscopy
12
parasite detection
12
parasite density
12
microscopy device
8
giemsa-stained blood
8
blood films
8
detection quantification
8
who-tdr malaria
8
parasite
7

Similar Publications

Biomimetic Approach to Counter Streptococcus mutans Biofilm: An In Vitro Study on Seashells.

Cureus

October 2023

Conservative Dentistry and Endodontics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, IND.

Aim This study aimed to investigate the anti-adherent property of the seashell surface and periostracum to prevent the formation of biofilm Materials and methods The seashells were initially collected from the natural urban beach, and an antibiofilm assay of the shells with and without periostracum was performed against . Furthermore, the seashells were analyzed with a stylus profilometer (Mitutoyo Surftest SJ-301, Mitutoyo America Corporation, Illinois, USA), atomic force microscope (AFM; Nanosurf Easyscan 2, Nanosurf Inc., USA), contact angle assessment, Fourier-transform infrared (FTIR) spectroscopy analysis, and scanning electron microscopy (SEM; JEOL USA, Inc.

View Article and Find Full Text PDF

The Vetscan Imagyst system (Zoetis) is a novel, artificial intelligence-driven detection tool that can assist veterinarians in the identification of enteric parasites in dogs and cats. This system consists of a sample preparation device, an automated digital microscope scanner, and a deep-learning algorithm. The EasyScan One scanner (Motic) has had good diagnostic performance compared with manual examinations by experts; however, there are drawbacks when used in veterinary practices in which space for equipment is often limited.

View Article and Find Full Text PDF

Rational design of electrocatalysts, including an increased catalytic surface area, a unique surface structure, and improved conductivity, for facilitating the hydrogen evolution reaction (HER) is emerging as an important issue. In this work, we consider the engineering of catalyst surfaces as an effective and feasible way to accelerate the HER kinetics. By etching the surface Fe of FeRu alloy nanoparticles (NPs) using hydrofluoric acid (HF), a distorted catalytic surface of FeRu NPs was formed.

View Article and Find Full Text PDF

Background: Microscopical screening of cytological samples for the presence of cancer cells at high throughput with sufficient diagnostic accuracy requires highly specialized personnel which is not available in most countries. Methods: Using commercially available automated microscope-based screeners (MotiCyte and EasyScan), software was developed which is able to classify Feulgen-stained nuclei into eight diagnostically relevant types, using supervised machine learning. the nuclei belonging to normal cells were used for internal calibration of the nuclear DNA content while nuclei belonging to those suspicious of being malignant were specifically identified.

View Article and Find Full Text PDF

Background: Microscopic examination of Giemsa-stained blood films remains the reference standard for malaria parasite detection and quantification, but is undermined by difficulties in ensuring high-quality manual reading and inter-reader reliability. Automated parasite detection and quantification may address this issue.

Methods: A multi-centre, observational study was conducted during 2018 and 2019 at 11 sites to assess the performance of the EasyScan Go, a microscopy device employing machine-learning-based image analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!