Download full-text PDF

Source
http://dx.doi.org/10.1007/s00586-022-07203-0DOI Listing

Publication Analysis

Top Keywords

correction identification
4
identification painful
4
painful disc
4
disc fissures
4
fissures magnetic
4
magnetic resonance
4
resonance images
4
images machine‑learning
4
machine‑learning modelling
4
correction
1

Similar Publications

Regulatory authorities typically require bioequivalence to be demonstrated by comparing pharmacokinetic parameters like area under the plasma concentration-time curve (AUC) and maximum plasma concentration (C). Because in certain cases, AUC and C alone may not be adequate to identify formulation differences in early and/or late segments of the dosing interval, partial AUCs (pAUCs) have been proposed as additional metrics to evaluate bioequivalence. Even though cut-off points for pAUCs are usually decided based on clinical relevance, the identification of the correct cut-off range remains elusive in many other cases and tends to contribute to increased pAUC estimate variabilities.

View Article and Find Full Text PDF

Magnesium Depletion Score and Mortality in Individuals with Metabolic Dysfunction Associated Steatotic Liver Disease over a Median Follow-Up of 26 Years.

Nutrients

January 2025

Division of Epidemiology, Vanderbilt Epidemiology Center, Department of Medicine, Vanderbilt University Medical Center, Vanderbilt University School of Medicine, Nashville, TN 37203, USA.

Unlabelled: Metabolic dysfunction associated steatotic liver disease (MASLD) has been associated with increased risks of all-cause and cardiovascular disease (CVD) mortality. Identification of modifiable risk factors that may contribute to higher risks of mortality could facilitate targeted and intensive intervention strategies in this population. This study aims to examine whether the magnesium depletion score (MDS) is associated with all-cause and CVD mortality among individuals with MASLD or metabolic and alcohol associated liver disease (MetALD).

View Article and Find Full Text PDF

Differentiation of and by Metabolite Profiles Obtained Using Gold Nanoparticles-Based Surface-Assisted Laser Desorption/Ionization Mass Spectrometry.

Pathogens

December 2024

Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, Rzeszów University of Technology, Powstańców Warszawy 6, 35-959 Rzeszów, Poland.

and are challenging to differentiate using methods such as phenotyping, 16S rRNA sequencing, or protein profiling through matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) due to their close relatedness. This study explores the potential for identifying and by incorporating reference spectra of metabolite profiles, obtained via surface-assisted laser desorption/ionization mass spectrometry (SALDI MS) employing gold nanoparticles (AuNPs), into the Bruker Biotyper database. Metabolite extracts from and cells were prepared using liquid-liquid extraction in a chloroform-methanol-water system.

View Article and Find Full Text PDF

In recent years, mobile laser measurement systems have markedly enhanced the capabilities of deformation detection and defect identification within metro tunnels, attributed to their superior efficiency, precision, and versatility. Nevertheless, challenges persist, including substantial equipment costs, inadequate after-sales support, technological barriers, and limitations in customization. This paper develops a mobile laser measurement system that has been specifically developed for the purpose of detecting deformation in metro tunnels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!