Background: Theoretically, artificial intelligence can provide an accurate automatic solution to measure right ventricular (RV) ejection fraction (RVEF) from cardiovascular magnetic resonance (CMR) images, despite the complex RV geometry. However, in our recent study, commercially available deep learning (DL) algorithms for RVEF quantification performed poorly in some patients. The current study was designed to test the hypothesis that quantification of RV function could be improved in these patients by using more diverse CMR datasets in addition to domain-specific quantitative performance evaluation metrics during the cross-validation phase of DL algorithm development.
Methods: We identified 100 patients from our prior study who had the largest differences between manually measured and automated RVEF values. Automated RVEF measurements were performed using the original version of the algorithm (DL1), an updated version (DL2) developed from a dataset that included a wider range of RV pathology and validated using multiple domain-specific quantitative performance evaluation metrics, and conventional methodology performed by a core laboratory (CORE). Each of the DL-RVEF approaches was compared against CORE-RVEF reference values using linear regression and Bland-Altman analyses. Additionally, RVEF values were classified into 3 categories: ≤ 35%, 35-50%, and ≥ 50%. Agreement between RVEF classifications made by the DL approaches and the CORE measurements was tested.
Results: CORE-RVEF and DL-RVEFs were obtained in all patients (feasibility of 100%). DL2-RVEF correlated with CORE-RVEF better than DL1-RVEF (r = 0.87 vs. r = 0.42), with narrower limits of agreement. As a result, DL2 algorithm also showed increasing accuracy from 0.53 to 0.80 for categorizing RV function.
Conclusions: The use of a new DL algorithm cross-validated on a dataset with a wide range of RV pathology using multiple domain-specific metrics resulted in a considerable improvement in the accuracy of automated RVEF measurements. This improvement was demonstrated in patients whose images were the most challenging and resulted in the largest RVEF errors. These findings underscore the critical importance of this strategy in the development of DL approaches for automated CMR measurements.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8996592 | PMC |
http://dx.doi.org/10.1186/s12968-022-00861-5 | DOI Listing |
Echocardiography
August 2024
Department of Pediatrics, University of California, San Diego, California, USA.
Purpose: We sought to assess the feasibility, reproducibility, and accuracy of conventional and newer echocardiographic measures of right ventricular (RV) systolic function in adolescent and young adult childhood cancer survivors treated with anthracyclines.
Methods: Echocardiography and cardiac magnetic resonance imaging (CMR) were acquired ≤60 days apart in prospectively recruited survivors and RV functional measures were quantitated by blinded observers. Repeat quantitation was performed in a subset to evaluate reproducibility.
Int J Cardiol
September 2024
Clinic for General and Interventional Cardiology/Angiology, Herz- und Diabeteszentrum, NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Bad Oeynhausen, Germany.
Background: Baseline right ventricular (RV) function derived from 3-dimensional analyses has been demonstrated to be predictive in patients undergoing transcatheter tricuspid valve repair (TTVR). The complex nature of these cumbersome analyses makes patient selection based on established imaging methods challenging. Artificial intelligence (AI)-driven computed tomography (CT) segmentation of the RV might serve as a fast and predictive tool for evaluating patients prior to TTVR.
View Article and Find Full Text PDFEchocardiography
April 2024
Department of Respiratory Medicine, Faculty of Medicine, Hokkaido University, Sapporo, Japan.
Background: Precapillary pulmonary hypertension (PH) is characterized by a sustained increase in right ventricular (RV) afterload, impairing systolic function. Two-dimensional (2D) echocardiography is the most performed cardiac imaging tool to assess RV systolic function; however, an accurate evaluation requires expertise. We aimed to develop a fully automated deep learning (DL)-based tool to estimate the RV ejection fraction (RVEF) from 2D echocardiographic videos of apical four-chamber views in patients with precapillary PH.
View Article and Find Full Text PDFMed Phys
December 2023
Department of Applied Computing, Michigan Technological University, Houghton, Michigan, USA.
Background: Functional assessment of right ventricle (RV) using gated myocardial perfusion single-photon emission computed tomography (MPS) heavily relies on the precise extraction of right ventricular contours.
Purpose: In this paper, we present a new deep-learning-based model integrating both the spatial and temporal features in gated MPS images to perform the segmentation of the RV epicardium and endocardium.
Methods: By integrating the spatial features from each cardiac frame of the gated MPS and the temporal features from the sequential cardiac frames of the gated MPS, we developed a Spatial-Temporal V-Net (ST-VNet) for automatic extraction of RV endocardial and epicardial contours.
J Clin Med
August 2022
Imaging Department, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy.
Background: The right ventricle (RV) plays a pivotal role in cardiovascular diseases and 3-dimensional echocardiography (3DE) has gained acceptance for the evaluation of RV volumes and function. Recently, a new artificial intelligence (AI)-based automated 3DE software for RV evaluation has been proposed and validated against cardiac magnetic resonance. The aims of this study were three-fold: (i) feasibility of the AI-based 3DE RV quantification, (ii) comparison with the semi-automatic 3DE method and (iii) assessment of 2-dimensional echocardiography (2DE) and strain measurements obtained automatically.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!