A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ascorbic Acid Sensor Based on CdS QDs@PDA Fluorescence Resonance Energy Transfer. | LitMetric

An ascorbic acid (AA) sensor was constructed based on the fluorescence resonance energy transfer (FRET) between CdS quantum dots (CdS QDs) and polydopamine (PDA) to detect trace AA sensitively. FRET occurred due to the broad absorption spectrum of PDA completely overlapped with the narrow emission spectrum of CdS QDs. The fluorescence of CdS QDs was quenched and in the "off" state. When AA was present, the conversion of DA to PDA was hindered and the FRET disappeared, resulting in the fluorescence of CdS QDs in an "on" state. Importantly, the degree of fluorescence recovery of CdS QDs displayed a desirable linear correlation with the concentration of AA in the range of 5.0-100.0 μmol/L, the linear equation is y=0.0119cAA+0.3113, and the detection limit is 1.16 μmol/L (S/N = 3, = 9). There was almost no interference with common amino acid, glucose and biological sulfhydryl small molecules to AA. Trace amount of AA in vitamin C tablets were determined and satisfactory results were obtained; the recoveries were observed to be 98.01-100.7%.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9000657PMC
http://dx.doi.org/10.3390/molecules27072097DOI Listing

Publication Analysis

Top Keywords

cds qds
20
ascorbic acid
8
acid sensor
8
fluorescence resonance
8
resonance energy
8
energy transfer
8
fluorescence cds
8
cds
7
fluorescence
5
qds
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!