Porous tantalum has been extensively used in orthopaedic surgery, including uncemented total knee arthroplasty (TKA). Favourable results were reported with earlier monobloc tibial components and the design evolved to modular implants. We aimed to analyse possible causes for extensive medial tibia bone loss, resulting in modular porous tantalum tibia baseplate fracture after primary TKA. Retrieved tissue samples were scanned with 3 MeV focused proton beam for Proton-Induced X-ray Emission (micro-PIXE) elemental analysis. Fractographic and microstructural analysis were performed by stereomicroscopy. A full 3D finite-element model was made for numerical analysis of stress-strain conditions of the tibial baseplate. Histological examination of tissue underneath the broken part of the tibial baseplate revealed dark-stained metal debris, which was confirmed by micro-PIXE to consist of tantalum and titanium. Fractographic analysis and tensile testing showed that the failure of the tibial baseplate fulfilled the criteria of a typical fatigue fracture. Microstructural analysis of the contact surface revealed signs of bone ingrowth in 22.5% of the surface only and was even less pronounced in the medial half of the tibial baseplate. Further studies are needed to confirm the responsibility of metal debris for an increased bone absorption leading to catastrophic tibial tray failure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8999729PMC
http://dx.doi.org/10.3390/ma15072575DOI Listing

Publication Analysis

Top Keywords

tibial baseplate
16
porous tantalum
12
total knee
8
tantalum tibia
8
microstructural analysis
8
metal debris
8
analysis
6
tibial
6
baseplate
5
knee replacement
4

Similar Publications

Minimum twenty-year follow-up of fixed-vs mobile-bearing total knee arthroplasty: Double blinded randomized trial.

J Clin Orthop Trauma

January 2025

Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, 2160 South First Avenue, 60153, Maywood, IL, USA.

Introduction: Mobile-bearing (MB) inserts, designed to minimize aseptic loosening and to reduce contact stresses leading to polyethylene wear, are an alternative to fixed-bearing (FB) inserts. Most studies have shown no significant difference between MB and FB constructs, and there is limited long-term data comparing the two constructs [1,2,3,4]. The purpose of this study was to report the outcomes of a randomized controlled trial comparing MB versus FB inserts on patients with minimum 20-year follow-up.

View Article and Find Full Text PDF

Background: Aseptic loosening is the most common aseptic failure modality following total knee arthroplasty. Recent literature suggests that the implant-cement interface is the "weak-link" in fixation and lipid contamination may drive this debonding pattern. Therefore, the purpose of this study was to determine if the "double-butter" technique would significantly decrease lipid contamination of the tibial tray.

View Article and Find Full Text PDF

Background And Purpose:  In total knee arthroplasty (TKA), an insert with ball-in-socket (BS) medial conformity (MC) and posterior cruciate ligament (PCL) retention restores kinematics closer to native than an insert with intermediate (I) MC. However, high medial conformity might compromise baseplate stability as indicated by maximum total point motion (MTPM). Using the BS MC insert with PCL retention, we aimed to determine whether (i) the baseplate is stable as indicated by mean MTPM < 0.

View Article and Find Full Text PDF

Background: The cementation technique is crucial for achieving adequate fixation and optimal survivorship in total knee arthroplasty (TKA). The thickness of the cement at the tibial bone-implant surface may be related to aseptic tibial loosening. However, to date, no studies have demonstrated a direct association between cement thickness and rates of aseptic tibial loosening.

View Article and Find Full Text PDF

Introduction: Malrotation of the tibial components in total knee arthroplasties is a common cause of pain and functional impairment. There are multiple methods used to establish the tibial component rotation, but there is still no consensus which method is the best.The objective of this study was to compare two of the most commonly used techniques, that is the use of self-alignment during passive range of motion (free-floating technique) versus the anterior cortex referencing method (Curve-on-curve technique).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!