Background: Corneal collagen cross-linking (CXL) has become the gold standard for mild and moderate stages to stop the progression of keratoconus. We analyzed some corneal topography indices to compare iontophoresis epi-on and iontophoresis epi-off techniques throughout a two-year follow-up. Methods: A total of 64 eyes of 49 patients who underwent CXL were recruited. In 30 eyes the epi-off technique was performed, whereas the remaining 34 eyes were treated with the epi-on technique. All patients underwent a complete ophthalmologic examination that included CDVA, central and thinnest corneal thickness, Schirmer test I, TBUT test, and the Ocular Surface Disease Index. Results: In both groups, a significant improvement in visual function was recorded. No statistically significant differences between Kmax, Mean K, Flat K, Steep K values were found. Statistically significant differences (p < 0.05) between the epi-on and epi-off groups’ pachymetry before and after 24 months follow-up as well as between the epi-on and epi-off groups’ topographically thinnest point in the immediate post-surgery and 24 months after surgery were recorded. Conclusion: Our study highlighted that both techniques are valid in mid-term corneal stabilization. The advantage of the new iontophoresis epi-off cross-linking technique could be found in a faster imbibing time of the cornea, therefore reducing surgical times, with a lower risk of complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9000184PMC
http://dx.doi.org/10.3390/jcm11071785DOI Listing

Publication Analysis

Top Keywords

corneal collagen
8
collagen cross-linking
8
iontophoresis epi-off
8
patients underwent
8
statistically differences
8
epi-on epi-off
8
epi-off groups’
8
epi-off
6
epi-on
5
corneal
5

Similar Publications

Purpose: Although mechanical injury to the cornea (e.g. chronic eye rubbing) is a known risk factor for keratoconus progression, how it contributes to loss of corneal integrity is not known.

View Article and Find Full Text PDF

Purpose: A detailed study of the physicochemical properties of SMILE-derived lenticules and evaluation of their drug delivery after loading with silver nanoparticles (AgNPs).

Methods: The lenticules were decellularized and modified with crosslinking concentrations of 0.01 (0.

View Article and Find Full Text PDF

The cornea is the primary refracting surface of the eye, requiring precise curvature to ensure optimal vision. Any distortion in its shape may result in significant visual impairment. Corneal ectasias, such as keratoconus (KC), is characterized by gradual thinning and protrusion of the thinned area, due to biomechanical weakening of the tissue, leading to astigmatism and vision loss.

View Article and Find Full Text PDF

Topography-guided, patterned, customized corneal crosslinking for non-invasive astigmatism correction.

Eye (Lond)

January 2025

Bio-manufacturing Engineering Laboratory, International Graduate School at Shenzhen, Tsinghua University, Shenzhen, Guangdong, China.

Objectives: To propose and evaluate a novel, non-invasive approach for enduring corneal astigmatism correction based on topography-guided, patterned, customized riboflavin-ultraviolet A corneal collagen crosslinking (CXL).

Methods: Astigmatism was modelled on both eyes of rabbits. A randomly selected eye of each rabbit was treated by the proposed CXL procedure with another eye as control.

View Article and Find Full Text PDF

Biochemical components of corneal stroma: a study on myopia classification based on Raman spectroscopy and deep learning methods.

Biomed Opt Express

January 2025

Center for Biomedical-photonics and Molecular Imaging, Advanced Diagnostic-Therapy Technology and Equipment Key Laboratory of Higher Education Institutions in Shaanxi Province, School of Life Science and Technology, Xidian University, Xi'an, Shaanxi 710126, China.

The study aimed to identify differences in the biochemical composition of corneal stroma lenses across varying degrees of myopia using Raman spectrum characteristics. Corneal stroma lens samples from 38 patients who underwent small incision lens extraction (SMILE) surgery, were categorized into low (n = 9, spherical power -3.00D), moderate (n = 23, spherical power < -3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!