A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Impact of Mechanical Ventilation Modes on Complications of Fiberoptic Bronchoscopy in Critically Ill Patients. | LitMetric

Objective: The effects of fiberoptic bronchoscopy are not elucidated in different mechanical ventilation modes. The present study aimed to evaluate the effects of fiberoptic bronchoscopy on lung mechanics, ventilation parameters, and gas exchange in 2 often-used modes, volume control and pressure control, in invasively ventilated patients followed up in the intensive care unit.

Material And Methods: Eligible patients were screened and included in the study after intensive care unit-fiberoptic bronchoscopy database search. Patients who underwent fiberoptic bronchoscopy under volume control and pressure control mechanical ventilation modes were compared. The primary outcome was the occurrence of any complication within the first 24 hours after the procedure, and secondary outcomes were changes in lung mechanics (dynamic lung compliance and airway resistance) and gas exchange (arterial partial pressures of oxygen and carbon dioxide).

Results: A total of 61 patients (median age: 69 years, 60.7% male) were included. Twenty-nine (47.5%) patients were ventilated in volume control mode and 32 (52.5%) in pressure control mode during the fiberoptic bronchoscopy procedure, and the median (interquartile range) duration of the procedure was 9 [8-11] minutes. Baseline dynamic lung compliance, airway resistance, arterial partial pressures of oxygen and carbon dioxide, and the fraction of inspired O2 were similar in both groups. After fiberoptic bronchoscopy, dynamic lung compliance decreased in both groups, and airway resistance and peak airway pressures increased but reached pre-fiberoptic bronchoscopy values at the 1st hour after the procedure. No significant differences were detected in both groups in terms of blood gas values and lung mechanics in the 1st and 24th hours after the procedure. In both groups, the 24th hour fraction of inspired O2 was the same as the pre-fiberoptic bronchoscopy values, but the ratio of arterial partial pressure of oxygen and the fraction of inspired O2 improved. No complications developed in patients within 24 hours after the procedure.

Conclusion: No differences were detected in terms of gas exchange and pulmonary mechanics, and complications in volume control and pressure control modes in critically ill intubated patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9450096PMC
http://dx.doi.org/10.5152/TurkThoracJ.2022.21149DOI Listing

Publication Analysis

Top Keywords

fiberoptic bronchoscopy
24
volume control
16
pressure control
16
mechanical ventilation
12
ventilation modes
12
lung mechanics
12
gas exchange
12
control pressure
12
dynamic lung
12
lung compliance
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!