The dry impinger method is commonly used for the determination of condensable particulate matter (CPM) emissions. The coil and chamber condenser is used to build different dry impinger methods for CPM sampling. The comparative analysis of coil and chamber condenser is performed in a laboratory experiment to evaluate the deviation caused by SO. Results showed that the positive deviation caused by SO in the chamber condenser is lower than that in the coil condenser under the same sampling conditions, especially under high humidity flue gas. The CPM emission characteristics from Hanchuan coal-fired power plant (CFPP) determined by both dry impinger methods are also investigated as well. The CPM and its most water-soluble ions (e.g., F, Cl, NO, SO, Na, Ca and NH) measured by method #2 (chamber condenser) are higher than that of method #1 (coil condenser). In addition, the esters in the CPM also increased with the CPM concentrations. Based on above evidences, it can be inferred that the dry impinger method with chamber condenser, will be recommended as the appropriate method for measuring CPM emitted from stationary sources, especially under the high humidity flue gas conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2022.155002DOI Listing

Publication Analysis

Top Keywords

dry impinger
20
chamber condenser
20
impinger method
12
condensable particulate
8
particulate matter
8
coal-fired power
8
power plant
8
coil chamber
8
impinger methods
8
deviation caused
8

Similar Publications

Ivermectin (IVM), a drug originally used for treating parasitic infections, is being explored for its potential applications in cancer therapy. Despite the promising anti-cancer effects of IVM, its low water solubility limits its bioavailability and, consequently, its biological efficacy as an oral formulation. To overcome this challenge, our research focused on developing IVM-loaded lipid polymer hybrid nanoparticles (LPHNPs) designed for potential pulmonary administration.

View Article and Find Full Text PDF

Although inhalation therapy represents a promising drug delivery route for the treatment of respiratory diseases, the real-time evaluation of lung drug deposition remains an area yet to be fully explored. To evaluate the utility of the photo reflection method (PRM) as a real-time non-invasive monitoring of pulmonary drug delivery, the relationship between particle emission signals measured by the PRM and in vitro inhalation performance was evaluated in this study. Symbicort® Turbuhaler® was used as a model dry powder inhaler.

View Article and Find Full Text PDF

There is a pressing need for efficacious therapies in the field of respiratory diseases and infections. Lipid nanocarriers, administered through aerosols, represent a promising tool for maximizing therapeutic concentration in targeted cells and minimizing systemic exposure. However, this approach requires the application of efficient and safe nanomaterials.

View Article and Find Full Text PDF

Development of a Novel Bronchodilator Vaping Drug Delivery System Based on Thermal Degradation Properties.

Pharmaceuticals (Basel)

December 2023

Mines Saint-Etienne, Université Jean Monnet Saint-Etienne, INSERM, Sainbiose U1059, Centre CIS, F-42023 Saint-Etienne, France.

This work aims to investigate bronchodilator delivery with the use of different vaping drug delivery systems (VDDS) by determining the dose equivalence delivered in relation to different references: a clinical jet nebulizer, a pMDI (pressurized metered dose inhaler) and a DPI (dry powder inhaler). Three different bronchodilators were used (terbutaline, salbutamol hemisulfate, ipratropium bromide). The e-liquids contained the active pharmaceutical ingredient (API) in powder form.

View Article and Find Full Text PDF

Purpose: In this study, we prepared inhalable buserelin microparticles using the spray freeze-drying (SFD) method for pulmonary drug delivery. Raffinose as a cryoprotectant carrier was combined with two levels of five different cyclodextrins (CDs) and then processed by SFD.

Methods: Dry powder diameters were evaluated by laser light scattering and morphology was determined by scanning electron microscopy (SEM).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!