Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Due to the lack of a correlation with the natural Strontium (Sr) isotopes, it is difficult to apply the isotope dilution (ID) method to an artificial radioactive mononuclide Strontium-90 (Sr), in inductively coupled plasma-quadrupole mass spectrometry (ICP-QMS). Meanwhile, online solid-phase extraction (SPE)-ICP-QMS (SPE-ICP-QMS) serves as an automatic sequential analytical technique for measuring the ultra-trace amounts of radionuclides; however, apparent assay values obtained using this method are often negatively affected by differences in the sample matrix composition between standard and actual samples. In this study, the pg L level of Sr was successfully measured by combining online SPE-ICP-QMS and the ID method with Sr/Sr ratios in one sample injection, without the radioactive standard. Although naturally occurring abundant isobaric Zr significantly influences Sr quantification during mass spectrometry, consecutive separations between automated SPE and dynamic reaction cell (DRC) oxidation enable Sr quantification, even in the presence of isobaric Zr (acceptable down to 5.7 × 10 of Sr/Zr in sample solution), using this method. Through this method, both radioactive Sr and naturally occurring Sr were simultaneously quantified using Sr-to-Sr and Sr-to-Sr ratios without radioactive Sr standard solutions. This simultaneous quantification of stable Sr and Sr was achieved within 15 min with good recovery rates. The limit of detection of Sr was 1.1 pg L (equivalent to radioactivity 5.6 Bq L) for a 10 mL injection. Finally, water collected from an actual contaminated water storage tank at the Fukushima Daiichi Nuclear Power Plant (Fukushima, Japan) was analyzed using the proposed method, and the obtained results agreed well with those obtained using conventional analytical methods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2022.123442 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!