Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A quantitative multi-class multi-residue analytical method was developed for the determination of veterinary drugs in milk by high-performance liquid chromatography - tandem mass spectrometry (HPLC-MS/MS). A total of 132 veterinary drugs investigated belonged to almost 15 classes including sulfonamides, β-lactams, tetracyclines, quinolones, macrolides, nitrofurans, nitroimidazoles, phenicols, lincosamides, pleuromutilins, macrocyclic lactones, quinoxaline antibiotics, benzimidazoles, anthelmintics, coccidiostats and some others. A magnetic solid-phase extraction procedure was developed using magnetic hypercrosslinked polystyrene (HCP/FeO) for the sample preparation prior to HPLC-MS/MS without deproteinization step. The results indicated recoveries of 85-107% for 14 sulfonamides, 85-120% for 13 β-lactams, 89-115% for 4 tetracyclines, 82-119% for 14 quinolones, 82-115% for 8 macrolides, 97-109% for 4 nitrofurans, 84-115% for 10 nitroimidazoles, 89-114% for 3 phenicols, 86-111% for 3 lincosamides, 97-102% for 2 pleuromutilins, 72-88% for 4 macrocyclic lactones, 87-104% for 4 quinoxaline antibiotics, 76-119% for 21 benzimidazoles, 79-115% for 12 anthelmintics, 81-118% for 12 coccidiostats and 75-119 % for 5 unclassified drugs, with relative standard deviations (RSDs) of less than 20%, and the LOQs ranged from 0.05 to 1 μg kg. This methodology was then applied to field-collected real milk samples and trace levels of some veterinary drugs were detected.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.foodchem.2022.132866 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!