Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Thoracic endovascular aortic repair (TEVAR) is a widely used procedure that has drastically changed the management of thoracic aortic diseases. We assess the effectiveness of supra-aortic debranching during antegrade TEVAR procedures with a retrospective analysis of our clinical experience.
Methods: Between December 2005 and April 2017, 55 patients underwent 64 TEVAR procedures. Among them, there were 8 male patients, mean age 72, who underwent hybrid antegrade stent-graft deployment. Particularly, for degenerative aneurysms of the aortic arch, 3 patients for aneurysm of descending thoracic aorta 3, for post-traumatic pseudoaneurysm 1, and for penetrating aortic ulcer 1 which had resulted in an aortoesophageal fistula. Proximal landing zones were Z0:1, Z1:3 and Z2:4. Type I hybrid aortic arch repair was performed in 1 case, carotid-carotid bypass in 2, carotid-subclavian in 5 and aorto-carotid in 1.
Results: The 30-day postoperative mortality was 12.5%. One patient suffered a temporary right hemiplegia which resolved after left aorto-carotid bypass. No endoleaks were observed postoperatively and in follow-up period. In the long term and a mean follow-up of 4.9 years, there were no deaths related to the stent-graft implantation or to revascularization procedures. Regarding the aortic arch rerouting procedure, there were no pseudoaneurysm or other anastomotic events.
Conclusions: Antegrade delivery of the endograft, combined with hybrid and revascularization procedures of the supra-aortic vessels is a safe treatment modality, in complex hostile anatomies. However, further improvements are recommended due to the presence of neurologic complications and reinterventions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.avsg.2022.03.023 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!